Is There Sufficient Training of Health Care Staff on Noise Reduction in Neonatal Intensive Care Units? a Pilot Study From Neonoise Project.
نویسندگان
چکیده
Evidence indicates that exposure to high levels of noise adversely affects human health, and these effects are dependent upon various factors. In hospitals, there are many sources of noise, and high levels exert an impact on patients and staff, increasing both recovery time and stress, respectively. The goal of this pilot study was to develop, implement, and evaluate the effectiveness of a training program (TP) on noise reduction in a neonatal intensive care unit (NICU) by comparing the noise levels before and after the implementation of the program. In total, 79 health professionals participated in the study. The measurements of sound pressure levels took into account the layout of the unit and locations of the main sources of noise. General results indicated that LAeq levels before implementation of the training program were often excessive, ranging from 48.7 ± 2.94 dBA to 71.7 ± 4.74 dBA, exceeding international guidelines. Similarly, following implementation of the training program, noise levels remained unchanged (54.5 ± 0.49 dBA to 63.9 ± 4.37 dBA), despite a decrease in some locations. There was no significant difference before and after the implementation of TP. However, a significant difference was found for Lp,Cpeak, before and after training staff, suggesting greater care by health care professionals performing their tasks. Even recognizing that a TP is quite important to change behaviors, this needs to be considered in a broader context to effectively control noise in the NICU.
منابع مشابه
The Effectiveness of Noise Reduction Interventions in Neonatal Intensive Care Units: A review Article
Background: High noises in the NICU are known to have negative effects on the health and wellness of hospitalized preterm infants. Various technologies for the care of preterm infants, extensive therapeutic interventions and communication between staff are among the causes of loud noise in these wards. The aim of this review article is to evaluate the effectiveness of noise reduction intervent...
متن کاملEffect of the Training of Nurses on the Reduction of Noise Pollution in Intensive Care Units
Background & Aims: Noise pollution is becoming a severe issue for the patients admitted in intensive care units (ICUs). For the reduction of noise pollution in hospitals, researchers recommend proper training and adherence to protocols. The present study aimed to assess the effect of the training of nurses on the reduction of noise pollution in ICUs. Materials & Methods: This clinical trial wa...
متن کاملDetermination of Noise Level and Its Sources in the Neonatal Intensive Care Unit and Neonatal Ward
Background: In Neonatal intensive care units (NICU) different sound intensities and frequencies are produced from different sources, which may exert undesirable physiological effects on the infants. The aim of this study was to determine the noise level and its sources in the NICU and neonatal ward of Al-Zahra Hospital of Rasht, Iran. Methods: In this descriptive cross-sectional study, the inte...
متن کاملEvaluation of the Effect of Sociodemographic Characteristics on the Satisfaction of Mothers in Neonatal Intensive Care Units in Turkey
Background: Patient and parent satisfaction is a significant indicator for the evaluation of quality of care in healthcare systems. This study aimed to evaluate the effect of sociodemographic characteristics on the satisfaction of the parents of newborns admitted in neonatal intensive care units (NICUs) in maternity and infant disease hospitals. Methods: This descriptive study was conducted on ...
متن کاملInvestigation of environmental stimuli in the neonatal intensive care unit of Ghaem Hospital in Mashhad
Introduction[N1] :One of these annoying stimuli and a major source of stress in the NICU is sound. In neonatal intensive care units, sounds with different intensities and frequencies are produced from different sources such as fan devices, intermittent alarms, ventilators, telephones, door opening and closing, and staff conversations; Studies have reported that the average noise level in the NI...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of toxicology and environmental health. Part A
دوره 78 13-14 شماره
صفحات -
تاریخ انتشار 2015