Microseparation and stripe wear in alumina-on-alumina hip implants.
نویسندگان
چکیده
The combination of materials that still has highest wear resistance for total hip replacement is ceramic-on-ceramic. However, brittleness is a major concern for ceramics: in vivo and in vitro studies on ceramic hip prostheses correlate microseparation with hip noise, ceramic wear, or ceramic liner damage. Ceramic microseparation can lead to edge load, ceramic head wear, and squeaking. The aim of this in vitro study was to investigate whether different angles of inclination influence the wear pattern of alumina-on-alumina hip joints with micro-separation during the swing phase. We also evaluated the wear rate obtained from this in vitro investigation with retrieval specimens obtained at 13 years' mean follow-up. The study was performed using a 12-station hip joint wear simulator (Shore Western, Monrovia, CA, USA) under bovine calf serum used as lubricant. Wear was evaluated by the gravimetric method and the test length was set at two million cycles. After two million cycles, a volumetric loss of 0.11 ±0.03 mm3 and 0.12 ±0.06 mm3 was observed, respectively, for 23° and 63° angles of inclination. In particular, the results obtained in this work revealed an increase of about 12-fold compared to previous results without microseparation conditions. No significant differences were observed between the two different inclinations on the wear patterns of the acetabular cups with a level of significance of a = 0.5. The location and general shape of the stripes wear were similar for the retrieved and simulator balls.
منابع مشابه
Degradation of alumina and zirconia toughened alumina (ZTA) hip prostheses tested under microseparation conditions in a shock device
This paper considers the degradation of alumina and zirconia toughened alumina vs. alumina for hip implants. The materials are as assumed to be load bearing surfaces subjected to shocks in wet conditions. The load is a peak of force; 9 kN was applied over 15 ms at 2 Hz for 800,000 cycles. The volumetric wear and roughness are lower for ZTA than for alumina. The long ZTA ageing did not seem to h...
متن کاملThe Influence of Edge Loading on the Wear of Fourth Generation Ceramic-on-Ceramic Bearing in Total Hip Replacements
INTRODUCTION Ceramic-on-ceramic (CoC) bearings in total hip replacements (THR) have become of great interest due to the substantial improvements in the manufacturing techniques and material properties [1]. They have substantially lower wear rates than metal or ceramic on polyethylene bearings [2] and wear particles were found to be less biologically active than particles produced by other types...
متن کاملWear of composite ceramics in mixed‐material combinations in total hip replacement under adverse edge loading conditions
Ceramic composites have performed very well under adverse edge loading conditions when used in like-on-like configurations, where the femoral head and acetabular cup are of the same material. The aim of this study was to determine the wear of pure alumina (Al2 O3 ), alumina toughened zirconia (ATZ) and zirconia toughened alumina (ZTA) when used in mixed bearing combinations, under edge loading ...
متن کاملEffects of in vitro shocks and hydrothermal degradation on wear of ceramic hip joints: Towards better experimental simulation of in vivo ageing
In an ageing world population, increasing the lifetime of orthopedic devices is of vital importance for reducing surgical risks for patients and reducing medical costs. Ceramic materials are gaining interest because of their hardness and chemical inertia with respect to metal prosthesis. Wear of the prosthetic couple (femoral head and cup) is one of the main rationales for using ceramic hip imp...
متن کاملComparative analysis of two different types of alumina-alumina hip prosthesis retrieved for aseptic loosening.
We compared and quantified the modes of failure and patterns of wear of 11 Mittelmeier and 11 Ceraver-Ostal retrieved alumina-alumina hip prostheses with reference to the corresponding clinical and radiological histories. Macroscopic wear was assessed using a three-dimensional co-ordinate measuring machine. Talysurf contacting profilometry was used to measure surface roughness on a microscopic ...