Highly Sensitive and Quick Detection of Acute Myocardial Infarction Biomarkers Using In2O3 Nanoribbon Biosensors Fabricated Using Shadow Masks.

نویسندگان

  • Qingzhou Liu
  • Noppadol Aroonyadet
  • Yan Song
  • Xiaoli Wang
  • Xuan Cao
  • Yihang Liu
  • Sen Cong
  • Fanqi Wu
  • Mark E Thompson
  • Chongwu Zhou
چکیده

We demonstrate a scalable and facile lithography-free method for fabricating highly uniform and sensitive In2O3 nanoribbon biosensor arrays. Fabrication with shadow masks as the patterning method instead of conventional lithography provides low-cost, time-efficient, and high-throughput In2O3 nanoribbon biosensors without photoresist contamination. Combined with electronic enzyme-linked immunosorbent assay for signal amplification, the In2O3 nanoribbon biosensor arrays are optimized for early, quick, and quantitative detection of cardiac biomarkers in diagnosis of acute myocardial infarction (AMI). Cardiac troponin I (cTnI), creatine kinase MB (CK-MB), and B-type natriuretic peptide (BNP) are commonly associated with heart attack and heart failure and have been selected as the target biomarkers here. Our approach can detect label-free biomarkers for concentrations down to 1 pg/mL (cTnI), 0.1 ng/mL (CK-MB), and 10 pg/mL (BNP), all of which are much lower than clinically relevant cutoff concentrations. The sample collection to result time is only 45 min, and we have further demonstrated the reusability of the sensors. With the demonstrated sensitivity, quick turnaround time, and reusability, the In2O3 nanoribbon biosensors have shown great potential toward clinical tests for early and quick diagnosis of AMI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Highly scalable, uniform, and sensitive biosensors based on top-down indium oxide nanoribbons and electronic enzyme-linked immunosorbent assay.

Nanostructure field-effect transistor (FET) biosensors have shown great promise for ultra sensitive biomolecular detection. Top-down assembly of these sensors increases scalability and device uniformity but faces fabrication challenges in achieving the small dimensions needed for sensitivity. We report top-down fabricated indium oxide (In2O3) nanoribbon FET biosensors using highly scalable radi...

متن کامل

Cardiac enzyme in emergency medicine

Objective: Acute chest pain is an important and frequently occurring symptom in patients. Chest pain is often a sign of ischemic heart disease. Chest pain due to suspected Acute Coronary Syndrome (ACS) is responsible for a large and ijncreasing number of hospital attendances and admissions. Current practice for suspected ACS involves troponin testing 10–12 hours after symptom o...

متن کامل

The effect of oxygen inhalation on cardiac biomarkers in patients presenting with acute ST-segment elevation myocardial infraction: A randomized clinical trial

Background: It is assumed giving oxygen to patients with acute myocardial infraction may increase the oxygenation of the ischemic tissue; however, the usefulness of oxygen in these patients has become a challenging topic. Thus, the present study aimed to determine the effect of oxygen inhalation on cardiac biomarkers in patients with acute myocardial infarction.    Methods: This randomized cli...

متن کامل

Printable Ultrathin Metal Oxide Semiconductor-Based Conformal Biosensors.

Conformal bioelectronics enable wearable, noninvasive, and health-monitoring platforms. We demonstrate a simple and straightforward method for producing thin, sensitive In2O3-based conformal biosensors based on field-effect transistors using facile solution-based processing. One-step coating via aqueous In2O3 solution resulted in ultrathin (3.5 nm), high-density, uniform films over large areas....

متن کامل

An Aptamer-based Biosensor for Troponin I Detection in Diagnosis of Myocardial Infarction

Background: Acute myocardial infarction (MI) accounts for one third of deaths. Cardiac troponin I (TnI) is a reliable biomarker of cardiac muscle tissue injury and is employed in the early diagnosis of MI.Objectives: In this study, a molecular method is introduced to early diagnosis of MI by rapid detection of TnI.Materials and Methods: The detection method was based on electrochemical aptasens...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • ACS nano

دوره 10 11  شماره 

صفحات  -

تاریخ انتشار 2016