Effective Tidal Volume for Normocapnia in Very-Low-Birth-Weight Infants Using High-Frequency Oscillatory Ventilation
نویسندگان
چکیده
PURPOSE Removal of CO₂ is much efficient during high-frequency oscillatory ventilation (HFOV) for preterm infants. However, an optimal carbon dioxide diffusion coefficient (DCO₂) and tidal volume (VT) have not yet been established due to much individual variance. This study aimed to analyze DCO₂ values, VT, and minute volume in very-low-birth-weight (VLBW) infants using HFOV and correlates with plasma CO₂ (pCO₂). MATERIALS AND METHODS Daily respiratory mechanics and ventilator settings from twenty VLBW infants and their two hundred seventeen results of blood gas analysis were collected. Patients were treated with the Dräger Babylog VN500 ventilator (Drägerwerk Ag & Co.) in HFOV mode. The normocapnia was indicated as pCO₂ ranging from 45 mm Hg to 55 mm Hg. RESULTS The measured VT was 1.7 mL/kg, minute volume was 0.7 mL/kg, and DCO₂ was 43.5 mL²/s. Mean results of the blood gas test were as follows: pH, 7.31; pCO₂, 52.6 mm Hg; and SpO₂, 90.5%. In normocapnic state, the mean VT was significantly higher than in hypercapnic state (2.1±0.5 mL/kg vs. 1.6±0.3 mL/kg), and the mean DCO₂ showed significant difference (68.4±32.7 mL²/s vs. 32.4±15.7 mL²/s). The DCO₂ was significantly correlated with the pCO₂ (p=0.024). In the receiver operating curve analysis, the estimated optimal cut-off point to predict the remaining normocapnic status was a VT of 1.75 mL/kg (sensitivity 73%, specificity 80%). CONCLUSION In VLBW infants treated with HFOV, VT of 1.75 mL/kg is recommended for maintaining proper ventilation.
منابع مشابه
Neonatal air leak syndrome and the role of high-frequency ventilation in its prevention.
Air leak syndrome includes pulmonary interstitial emphysema, pneumothorax, pneumomediastinum, pneumopericardium, pneumoperitoneum, subcutaneous emphysema, and systemic air embolism. The most common cause of air leak syndrome in neonates is inadequate mechanical ventilation of the fragile and immature lungs. The incidence of air leaks in newborns is inversely related to the birth weight of the i...
متن کاملComparison of motor development of low birth weight (LBW) infants with and without using mechanical ventilation and normal birth weight infants
Background: To determine whether using mechanical ventilation in neonatal intensive care unit (NICU) influences motor development of low birth weight (LBW) infants and to compare their motor development with normal birth weight (NBW) infants at the age of 8 to 12 months using Peabody Developmental Motor Scale 2 (PDMS-2). Methods: This cross sectional study was conducted on 70 LBW infants in ...
متن کاملComparison of respiratory indices in predicting response to high frequency oscillatory ventilation in very low birth weight infants with respiratory distress syndrome.
To evaluate the predictive values of oxygenation index (OI), arterial-alveolar oxygen tension ratio (a/APO)2, and alveolar-arterial oxygen gradient ((A-a)DO2) for early recognition of responsiveness to high frequency oscillatory ventilation (HFOV) in very low birth weight infants with respiratory distress syndrome (RDS), 23 infants who received HFOV treatment for severe RDS after failing to be ...
متن کاملNormocapnic high frequency oscillatory hyperventilation increases oxygenation in pigs.
High frequency oscillatory ventilation (HFOV), contrary to conventional ventilation, enables a safe increase in tidal volume (V(T)) without endangering alveoli by volutrauma or barotrauma. The aim of the study is to introduce the concept of normocapnic high frequency oscillatory hyperventilation and to assess its effect upon oxygen gain under experimental conditions. Laboratory pigs (n = 9) wer...
متن کاملInhaled iloprost in the treatment of pulmonary hypertension in very low birth weight infants: a report of two cases.
We treated 2 very low birth weight (VLBW) infants with respiratory distress syndrome suffering from refractory hypoxic respiratory failure complicated with severe pulmonary hypertension with inhaled iloprost. The first infant was an 800 gram male and the second case was a 920 gram female. Echocardiography revealed a right to left shunt through patent duct in the first case; suprasystemic pulmon...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 59 شماره
صفحات -
تاریخ انتشار 2018