Determination of log P values of new cyclen based antimalarial drug leads using RP-HPLC.
نویسندگان
چکیده
Lipophilicity, expressed by log P, is an important physicochemical property of drugs that affects many biological processes, including drug absorption and distribution. The main purpose of this study to determine the log P values of newly discovered drug leads using reversed-phase high-performance liquid chromatography (RP-HPLC). The reference standards, with varying polarity ranges, were dissolved in methanol and analyzed by RP-HPLC using a C18 column. The mobile phase consisted of a mixture of acetonitrile, methanol and water in a gradient elution mode. A calibration curve was plotted between the experimental log P values and obtained log k values of the reference standard compounds and a best fit line was obtained. The log k values of the new drug leads were determined in the same solvent system and were used to calculate the respective log P values by using the best fit equation. The log P vs. log k data gave a best fit linear curve that had an R2 of 0.9786 with Pvalues of the intercept and slope of 1.19 x 10(-6) and 1.56 x 10(-10), respectively, at 0.05 level of significance. Log P values of 15 new drug leads and related compounds, all of which are derivatives of macrocyclic polyamines and their metal complexes, were determined. The values obtained are closely related to the calculated log P (Clog P) values using ChemDraw Ultra 12.0. This experiment provided efficient, fast and reasonable estimates of log P values of the new drug leads by using RP-HPLC.
منابع مشابه
RP-HPLC method development and validation for determination of eptifibatide acetate in bulk drug substance and pharmaceutical dosage forms
A new, rapid, economical and isocratic reverse phase high performance liquid chromatography (RP-HPLC) method was developed for the determination of eptifibatide acetate, a small synthetic antiplatelet peptide, in bulk drug substance and pharmaceutical dosage forms. The developed method was validated as per of ICH guidelines. The chromatographic separation was achieved isocratically on C18 colum...
متن کاملRP-HPLC method development and validation for determination of eptifibatide acetate in bulk drug substance and pharmaceutical dosage forms
A new, rapid, economical and isocratic reverse phase high performance liquid chromatography (RP-HPLC) method was developed for the determination of eptifibatide acetate, a small synthetic antiplatelet peptide, in bulk drug substance and pharmaceutical dosage forms. The developed method was validated as per of ICH guidelines. The chromatographic separation was achieved isocratically on C18 colum...
متن کاملSimultaneous RP-HPLC and UV Spectroscopic Method Development and Validation for Estimation of Ibandronate Sodium in Bulk and Pharmaceutical Dosage Form
The present study describes a simple, accurate, precise and cost effective UV-Vis Spectroscopic and RP-HPLC method for the estimation of Ibandronate sodium (IBN). The determination of Ibandronate sodium (IBN) was performed by both UV and RP-HPLC method using 215 nm as the determination wavelength. The drug was dissolved in NaOH solution (0.1N NaOH) for estimation in UV and in distilled water fo...
متن کاملDetermination of Juglone (5-hydroxy 1,4-naphthoquinone) in Pterocarya fraxinifolia by RP-HPLC
A method for determination of juglone in leaves and hulls of Pterocarya fraxinifolia was developed, based on RP-HPLC. This compound was extracted from leaves and hulls by chloroform refluxing about 2 hours. The chloroform was evaporated under low pressure at 50 ºC to produce a dry residue. The remained materials were dissolved in acetonitrile to be used for determination of this compound....
متن کاملQuantification of Polyethylene Glycol Esters of Methotrexate and Determination of Their Partition Coefficients by Validated HPLC Methods
Conjugation of methotrexate (MTX) (MW 454) with different molecular weights of polyethylene glycol (PEG) including methoxy-peg (mpeg) 750 D and 5000 D and diol-peg 35000 D led to compounds that are physicochemically highly different from the parent compound, MTX. In this study, an HPLC system consisting of C8 column and UV detector (?=342 nm), using a mixture of 30:70 v/v phosphate-citrate buff...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Die Pharmazie
دوره 69 9 شماره
صفحات -
تاریخ انتشار 2014