The Graphite Calorimeter as a Standard of Absorbed Dose for Cobalt-60 Gamma Radiation

نویسنده

  • Robert Loevinger
چکیده

Absorbed dose to water in a cobalt-60 gamma-ray beam has been determined using a thick-walled graphite ionization chamber. The chamber was calibrated in a graphite phantom against a graphite calorimeter, and the graphite calibration factor was converted to a water calibration factor using published energy absorption coefficient ratios and a measured replacement factor. Comparisons between the graphite and water measurements were made at pairs of points that were scaled in position according to the ratio of electron densities, so that the photon spectra were the same for the two points in a given pair. Measurements performed in graphite over a wide range of phantom depths, field sizes, and source distances, showed that the calibration factor varies slowly with the phantom depth and field size, and probably has a negligible dependence on source distance. By comparison with the thick-walled chamber in a cobalt-60 gamma-ray beam, a secondary ionization chamber can be calibrated in terms of absorbed dose to water with an estimated uncertainty of about ± 1 percent.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The UK primary standard calorimeter for photon-beam absorbed dose measurement.

A description is given of the UK primary standard graphite calorimeter system. The calorimeter measures absorbed dose to graphite for photon radiations from 60Co to 19 MV x-rays, and is the basis of the NPL therapy-level absorbed dose to water calibration service. Absorbed dose to graphite from the photon calorimeter has been compared with three other standards: an ionization chamber and cavity...

متن کامل

A Polystyrene-Water Calorimeter

The paper describes a new type of calorimeter that can be quickly put into operation for determining absorbed dose at a point in polystyrene. It also describes a unique method of decreasing drifts in electrical signals caused by temperature gradients. Two calibrated thermistors were placed close together between sandwiched polystyrene discs that were immersed in water. The assembly was irradiat...

متن کامل

Calorimetry for Absorbed-dose Measurements at BNM-LNHB

At BNM-LNHB, the references in terms of absorbed dose to water are based on graphite calorimeter measurements. In the cobalt-60 beam, measurements were performed directly with the graphite calorimeter in a graphite phantom. Absorbed dose to water in a water phantom was then determined using a transfer method by means of relative measurements made with ionisation chambers and Fricke dosimeters. ...

متن کامل

Development of a new in-water-phantom graphite calorimeter for the measurement of absorbed dose to water in medium energy x-ray beams

This paper summarizes the progress on the construction of a graphite calorimeter for the measurement of absorbed dose to water Dw in medium-energy filtered x-ray qualities, as part of the EMRPfunded project “Metrology for radiotherapy using complex radiation fields” (MetrExtRT, http://radiotherapyemrp.eu/). The design and the construction of a new primary standard for absorbed dose to water (Dw...

متن کامل

An Absorbed Dose Water Calorimeter: Theory, Design, and Performance

Two calibrated thermistors sandwiched between two insulative polyethylene films were immersed in a 30 cm cube of water having a low thermal diffusivity. The product of the specific heat of water and temperature rise gave the combined effect of the local absorbed dose and any heat defect at a position along a temperature profile produced by cobalt-60 irradiation. The dose rate was near 18 mGy/s ...

متن کامل