Ricean over Gaussian modeling in magnitude fMRI Analysis – Added Complexity with Negligible Practical Benefits
نویسندگان
چکیده
It is well-known that Gaussian modeling of functional Magnetic Resonance Imaging (fMRI) magnitude time-course data, which are truly Rice-distributed, constitutes an approximation, especially at low signalto-noise ratios (SNRs). Based on this fact, previous work has argued that Rice-based activation tests show superior performance over their Gaussian-based counterparts at low SNRs and should be preferred in spite of the attendant additional computational and estimation burden. Here, we revisit these past studies and after identifying and removing their underlying limiting assumptions and approximations, provide a more comprehensive comparison. Our experimental evaluations using ROC curve methodology show that tests derived using Ricean modeling are substantially superior over the Gaussian-based activation tests only for SNRs below 0.6, i.e SNR values far lower than those encountered in fMRI as currently practiced. Copyright c © 2013 John Wiley & Sons, Ltd.
منابع مشابه
Ricean over Gaussian modelling in magnitude fMRI Analysis-Added Complexity with Negligible Practical Benefits.
It is well-known that Gaussian modeling of functional Magnetic Resonance Imaging (fMRI) magnitude time-course data, which are truly Rice-distributed, constitutes an approximation, especially at low signal-to-noise ratios (SNRs). Based on this fact, previous work has argued that Rice-based activation tests show superior performance over their Gaussian-based counterparts at low SNRs and should be...
متن کاملImproved Activation Detection via Rice-Distributed fMRI Time Series Modeling
Two developments in fMRI magnitude time series modeling, namely, the incorporation of temporal dependence and the Ricean distribution, have been separated by a distributional “mismatch”: such time series modeling is largely based upon Gaussian-distributional-based extensions to the general linear model, which precludes its use under Ricean modeling. We bridge this gap by applying AR(p) errors t...
متن کاملOn Estimating the Parameters of the Complex fMRI Time Course Model
In functional magnetic resonance imaging, voxel time courses are complex valued but are traditionally converted to real magnitude-only ones. At a large signal-to-noise ratio (SNR), the magnitude-only Ricean distriution is approximated by a normal distribution that has been suggested as reasonable in magnitude-only magnetic resonance images for an SNR of 5 and potentially as low as 3. A complex ...
متن کاملParameter estimation in the magnitude-only and complex-valued fMRI data models.
In functional magnetic resonance imaging, voxel time courses are complex-valued data but are traditionally converted to real magnitude-only data ones. At a large signal-to-noise ratio (SNR), the magnitude-only data Ricean distribution is approximated by a normal distribution that has been suggested as reasonable in magnitude-only data magnetic resonance images for an SNR of 5 and potentially as...
متن کاملPerformance Analysis of ZF Pre-Coder and Extended Joint Channel Estimation Method in Downlink CDMA with HPA
In the down link scenario of code division multiple access (CDMA) systems, multi user detectors (MUDs) such as linear de-correlating detector (LDDs) provide satisfactory symbol error rates (SERs) at the expense of much increased complexity, they require all active users’ spreading sequences, which is impractical from privacy point of view. To overcome this impracticality, a simple matched filte...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2013