The Vista system: a new bipolar resection device for endourological procedures: comparison with conventional resectoscope.

نویسندگان

  • Gunnar Wendt-Nordahl
  • Axel Häcker
  • Oliver Reich
  • Bob Djavan
  • Peter Alken
  • Maurice Stephan Michel
چکیده

OBJECTIVE Conventional transurethral resection of the prostate (TURP) uses a monopolar electrocautery system in which the current passes from the active electrode through the patient's body towards the return plate and may cause distant negative effects. In this study a new developed resection device, the Vista system, using a bipolar electrocautery system and 0.9% sodium chloride solution for irrigation, was evaluated in an ex-vivo model. METHODS The modified model of the isolated blood perfused kidney was used to determine cutting qualities, ablation rate, blood loss and coagulation depth of the bipolar resectoscope. After ablating the renal tissue of a perfused kidney in a surface area, blood loss was semiquantitatively determined. Afterwards samples were taken and processed for histological evaluation of the coagulation depth. We compared the new bipolar resection device against a conventional monopolar resectoscope. RESULTS We found good cutting qualities of the bipolar resectoscope although it is more difficult to start a cut. The ablation rate is determined by the width of the electrode and is similar to the standard device (30 cm(2)/min). The bleeding is reduced with increasing output powers (26.13 +/- 6.15 g/min (level 5); 20.49 +/- 5,47 g/min (level 6); 13.16 +/- 5,47 g/min (level 7); 10.43 +/- 4.76 g/min (level 8) and lower compared to a conventional monopolar resectoscope (17.08 +/- 4.47 g/min). The coagulation depth increases with higher output powers but is reduced compared to the standard device (118 +/- 22 microm (level 5); 121 +/- 23 microm (level 6); 141 +/- 62 microm (level 7); 163 +/- 30 microm (level 8) versus 287 +/- 57 (monopolar resectoscope)). CONCLUSION Our results with the bipolar resection device for TURP suggest that it may offer an alternative to conventional TURP. As active and the return electrode are placed on the resectoscope, high current densities are achieved locally and complications caused by distant negative effects of the current are theoretically reduced in vivo. Furthermore the risk of TUR syndrome is theoretically eliminated by using physiological sodium chloride solution for irrigation. To prove the clinical significance of our ex-vivo findings, clinical studies including large numbers of patients have to be performed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bipolar resection of the bladder and prostate – Initial experience with a newly developed regular sized loop resectoscope

OBJECTIVE Bipolar transurethral resection (TUR) has been introduced in the clinical practice nowadays. Benefits from bipolar TUR are represented by the use of saline irrigation, which avoids hypoosmotic hyperhydration (TUR-Syndrome), as well as by the reduced risk of obturator nerve stimulation. However, the previously introduced smaller bipolar resection loop caused prolonged operating-time. W...

متن کامل

Transurethral Resection of the Prostate with a Bipolar Tissue Management System Compared to Conventional Monopolar Resectoscope: One-Year Outcome

The purpose of the present study was to evaluate the efficacy and safety of bipolar transurethral prostatectomy (TURP) using the Gyrus PlasmaKinetic System compared with conventional monopolar TURP. This study included 102 patients with benign prostatic hyperplasia (BPH) who underwent TURP from January 2003 to March 2005. In all, 49 consecutive patients had bipolar and 53 had monopolar TURP. Al...

متن کامل

Bipolar transurethral resection in saline (TURis): outcome and complication rates after the first 1000 cases.

OBJECTIVE TURis((R)) is an emerging technique that shows the same efficacy of monopolar resection. However, there is currently little available data on the safety of bipolar devices. We assessed outcome and safety of TURis on a large cohort of patients with at least 6 months' follow-up. PATIENTS AND METHODS Between January 2006 and October 2007, 1000 consecutive transurethral resection (TUR),...

متن کامل

Successful Reconstruction of Nerve Defects Using Distraction Neurogenesis with a New Experimental Device

Introduction: Repair of peripheral nerve injuries is an intensive area of challenge and research in modern reconstructive microsurgery. Intensive research is being carried out to develop effective alternatives to the standard nerve autografting, avoiding its drawbacks. The aim of the study was to evaluate the effectiveness of a newly designed mechanical device for the reconstruction of the...

متن کامل

Saline-Filled Laparoscopic Surgery: A Basic Study on Partial Hepatectomy in Rabbit Model Short Title: Saline-filled laparoscopic surgery

Background There is still a poor understanding of the effects of pneumoperitoneum with insufflation of carbon dioxide gas (CO2) on malignant cells, and pneumoperitoneum has a negative impact on cardiopulmonary responses. A novel saline-filled laparoscopic surgery (SAFLS) is proposed, and the technical feasibility of performing saline-filled laparoscopic partial hepatectomy (LPH) was evaluated i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European urology

دوره 46 5  شماره 

صفحات  -

تاریخ انتشار 2004