Amperometric Detection of Nitric Oxide with Microsensor in the Medium of Seawater and Its Applications
نویسندگان
چکیده
Amperometric detection of nitric oxide with ISO-NOPMC NO microsensors (WPI) is systemically studied in the six media including seawater. The linear range of the microsensor for NO was from 10 to 10 mol/l and the detection limit was 4.2×10 mol/L(S/N=2). With this method, we provide preliminary evidence that NO production could be a general attribute of marine alga (Haeterosigma akashiwo). Experiment conducted with inhibitor of uncoupler 2,4-DNP (2,4-dinitropheno) revealed that NR (nitrate reductase) activity is responsible for NO formation.
منابع مشابه
Highly Sensitive Amperometric Sensor Based on Gold Nanoparticles Polyaniline Electrochemically Reduced Graphene Oxide Nanocomposite for Detection of Nitric Oxide
A sensitive electrochemical sensor was fabricated for selective detection of nitric oxide (NO) based on electrochemically reduced graphene (ErGO)-polyaniline (PANI)-gold nanoparticles (AuNPs) nanocomposite. It was coated on a gold (Au) electrode through stepwise electrodeposition to form AuNPs-PANI-ErGO/Au electrode. The AuNPs-PANI-rGO nanocomposite was characterized by Field Emission Scanning ...
متن کاملThe Electrochemical Detremination of Nitric Oxide in Seawater Media with Microelectrodes
The electrochemical determination of nitric oxide in seawater with microelectrodes is reported in this paper. Two electrodes, ISO-NOPMC microsensor and modified platinum microelectrode, are evaluated for their performance in seawater. The peak current is found to be linear with the NO concentration in the range 1×10-1.2×10 mol/l for both microelectrodes. The detection limit of ISO-NOPMC microse...
متن کاملAMPEROMETRIC MICROBIOSENSOR FOR THE DETERMINATION OF CHOLINE
The construction and performance of an amperometric microbiosensor for the determination of choline chloride by immobilizing choline oxidase on a cellulose acetate membrane are described. The procedure of choline determination involved the electrochemical detection of enzymatically generated hydrogen peroxide. This microsensor has a linear response between 0.038-0.1 mM choline chloride. The...
متن کاملDeveloped Method Application for Nitrite Ion (NO2¯ ) Analysis of Tib -186 Macrophage Like Cell Lines by Rapid Isocratic HPLC System with High Sensitive Glassy Carbon Electrochemical Detector
A rapid isocratic method of high performance liquid chromatography system (HPLC) with a glassy carbon working electrode of electrochemical detector is set up for quantitative detection of trace amount of nitrite ion (NO2¯) in aqueous protein containing cell lysate, cell media, plasma, serum, urine and other body fluids. The solid extraction reversed phase cartridges ...
متن کاملP-90: The Effect of Nitric Oxide on Mouse Oocyte in Vitro Maturation in Two and Three Dimensional Conditions
Background: In vitro culture of ovarian follicles may preserve fertility in women with premature ovarian failure due to cancer .It seems that creation a condition that could maintain cellular communications and supports growth of follicles to produce mature oocytes appear to be essential. Nitric oxide (NO) has been recently shown to act with a dual action in mouse oocyte meiotic maturation depe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 5 شماره
صفحات -
تاریخ انتشار 2005