Volumetric intensity-modulated arc therapy vs conventional intensity-modulated radiation therapy in nasopharyngeal carcinoma: a dosimetric study
نویسندگان
چکیده
Dosimetric comparisons between RapidArc (RA) and conventional Intensity-Modulated Radiation Therapy (IMRT) techniques for nasopharyngeal carcinoma (NPC) were performed to address differences in dose coverage of the target, sparing of organs-at-risk (OARs), delivery of monitor units (MUs) and time, to assess whether the RA technique was more beneficial for treatment of NPC. Eight NPC patients (Stages I-IV), who had completed RA treatment, were selected for this study. Computed tomography data sets were re-planned using 7-fields fixed beam IMRT. Quantitative measurements of dose-endpoint values on the dose-volume histograms were carried out for evaluation of: (i) dose homogeneity (D5% - D(95%)); (ii) degree of conformity (CI9(5%)); (iii) tumor control probability (TCP); (iv) doses to OARs; (v) normal tissue complication probability (NTCP); (vi) treatment time; and (vii) MUs. RA plans achieved better dose conformity and TCP in planning target volumes (PTVs). Target dose homogeneity was not as high as for IMRT plans. Doses to tempero-mandibular joints, clavicles, parotid glands and posterior neck, and their NTCPs were significantly lower in RA plans (P < 0.05). Mean doses to the brainstem and spinal cord were slightly lower in IMRT plans. RA plans allowed for a mean reduction in MUs by 78% (P = 0.006), and a four-fold reduction in treatment delivery times, relative to IMRT plans. RA plans showed superior, or comparable, target coverage and dose conformity in PTVs, but at the expense of inferior dose homogeneity. RA plans also achieved significant improvements in dose reduction to OARs and healthy tissue sparing. A significant reduction in treatment delivery time for RA treatment technique was also noted.
منابع مشابه
Clustering of nasopharyngeal carcinoma intensity modulated radiation therapy plans based on k-means algorithm and geometrical features
Background: The design of intensity modulated radiation therapy (IMRT) plans is difficult and time-consuming. The retrieval of similar IMRT plans from the IMRT plan dataset can effectively improve the quality and efficiency of IMRT plans and automate the design of IMRT planning. However, the large IMRT plans datasets will bring inefficient retrieval result. Materials and Methods: An intensity-m...
متن کاملRadiobiological Model-Based Comparison of Three-Dimensional Conformal and Intensity-Modulated Radiation Therapy Plans for Nasopharyngeal Carcinoma
Introduction: Radiobiological modeling of radiotherapy plans are used for treatment plan comparisons. The current study aimed to compare the three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) plans for nasopharyngeal cancer using radiobiological modeling. Materials and Methods: This study was conducted on 10 patients with nasopharyngeal carci...
متن کاملDosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol
Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...
متن کاملVolumetric Modulated Radiation Therapy and Intensity Modulated Radiation Therapy for Lung Cancer: Literature Review
Intensity modulated radiation therapy (IMRT) and volumetric intensity-modulated arc therapy (VMAT) are two commonly used modalities to treat lung cancer. VMAT has established increasing interest in treating cancer due to shorter treatment delivery time and less number of monitor units (MUs). The main purpose of this article was to review the relevant current literature on planning studies for l...
متن کاملOptimization of prostate cancer radiotherapy using of a spacer gel, volumetric modulated arc therapy and a single biological organ at risk objective
Background: The aim was to evaluate the benefit of technical advances for treatment planning: introduction of a hydrogel spacer, VMAT (volumetric modulated arc therapy) and a single biological organ at risk objective for the rectum and bladder. Initial standard was a step-and-shoot IMRT (intensity modulated radiotherapy) without a spacer and conventional organ at risk objectives. Material...
متن کامل