Evaluation of various methods of point-of-care testing of haemoglobin concentration in blood donors.

نویسندگان

  • Abhay Singh
  • Anju Dubey
  • Atul Sonker
  • Rajendra Chaudhary
چکیده

BACKGROUND Point-of-care testing (POCT) devices for determining pre-donation haemoglobin (Hb) concentrations mark the advent of advanced technology for blood banks. POCT devices have undergone several improvements including changes in testing methodology and size of device, befitting the needs of blood donors and blood banks in terms of safety and quality of blood components. This study was planned to evaluate the suitability of non-invasive and invasive POCT devices for blood donor Hb screening. MATERIAL AND METHODS Pre-donation Hb in apparently healthy blood donors was measured by a non-invasive spectrophotometric based method (NBM-200, OrSense) and an invasive method utilizing reagent free cuvettes (DiaSpect) along with a device using sodium azide-coated cuvettes (HemoControl, EKF diagnostic GmbH). The performance of the devices was evaluated by comparison with the reference method, i.e. an automated cell counter (KX-21). RESULTS Hb was measured in 485 prospective blood donors. DiaSpect hemoglobin T system was found to be the most sensitive method of POCT for Hb (sensitivity 98.1%) followed by HemoControl (sensitivity 86.8%). NBM-200 was the least sensitive method (sensitivity 71.7%). The intraclass correlation coefficient was highest for DiaSpect (0.78), followed by HemoControl (0.77) and NBM-200 (0.43). The variation of results on repeat testing was high for NBM-200 with a coefficient of variation of 4.28%, compared to 2.19% for DiaSpect. On comparing the mean testing time, DiaSpect (1.9 seconds) was found to be significantly quicker than the other two POCT devices (p<0.001). DISCUSSION NBM-200 has the apparent advantage of eliminating pain but also a substantial possibility of causing ineligible donors to be accepted. DiaSpect was fast and accurate, with its results showing perfect agreement with those of the standard method. It is, therefore, aptly suited for screening donors in blood banks.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Seroprevalence of Transfusion Transmissible Infections among Blood Donors in a Tertiary Care Hospital of North India

Background: Unsafe transfusion practices put patients at high risk of transfusion transmissible infections. We aimed to evaluate the prevalence of transfusion transmissible infections (including Human Immunodeficiency Virus [HIV] 1 and 2, Hepatitis B Virus [HBV], Hepatitis C Virus (HCV) and syphilis) during a period of 18 months among blood donors in the Blood Bank of Lady Hardinge Medical Coll...

متن کامل

Evaluation of Effect of Plasmas Prepared from Packed Red Blood Cells at Different Weeks on Production of Nitric Oxide (NO) and Malondialdehyde (MDA) from Peripheral Blood Mononuclear Cells in Vitro

Introduction: In present study, we evaluated the effect of plasma collected from packed red blood cells (PRBCs) at various weeks after donation on peripheral blood mononuclear cells (PBMCs). Methods: In this experimental study, plasma prepared from twenty PRBCs in the first, second, fourth, and fifth weeks after donation. PBMCs were also isolated from healthy donors and treated with different c...

متن کامل

Prevalence of Occult Hepatitis B Infection Among Blood Donors with HBsAg Negative and HBcAb Positive by Real Time PCR in South of Iran

Abstract   Background & aim: Occult hepatitis B virus infection in blood donors threats the safety of the blood supply.  It is characterized by detection of low viral DNA in the serum subjects who have negative test for Hepatitis B surface antigen (HBsAg). The aim of this study was to assess the prevalence of occult hepatitis B virus infection among HBsAg negative and HBcAb positive in blood ...

متن کامل

Evaluation of the validity of a rapid method for measuring high and low haemoglobin levels in whole blood donors.

BACKGROUND Haemoglobin screening methods need to be highly sensitive to detect both low and high haemoglobin levels and avoid unnecessary rejection of potential blood donors. The aim of this study was to evaluate the accuracy of measurements by HemoCue in blood donors. MATERIALS AND METHODS Three hundred and fourteen randomly selected, prospective blood donors were studied. Single fingerstick...

متن کامل

Motivation and Intention to Future Donation among Blood Donors Attending a Tertiary Care Hospital Blood Bank in Kerala

Background and Aims: This study aims to identify the level of motivation among blood donors and their intention to donate again and suggest remedial measures to rectify de-motivating influences. Materials and Methods: A self-administered questionnaire was distributed among donors to collect data on variables related to the objective. Results: Most donors were men aged 18-24 years, graduates, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Blood transfusion = Trasfusione del sangue

دوره 13 2  شماره 

صفحات  -

تاریخ انتشار 2015