A small-volume constant-flow air sampling device for thermal desorption GC analysis.
نویسندگان
چکیده
A glass syringe with disposable membrane filters was tested as a constant-flow air sampling device. The principle of this sampling device is straightforward: when the syringe is inverted vertically, the syringe plunger falls at a constant speed if an appropriate flow restrictor is connected at the syringe inlet. In case of a 100 ml syringe with two Teflon membrane filters of 0.50 microns in pore size and 3 mm in diameter, the flow rate was 3 ml/min. The flow rate was constant for a 15-minute sampling period when two to eight filters were used as a flow restrictor. A sample volume of less than 50 ml is sufficient for the determination of organic solvent vapor at the ppm level, when gas chromatography with thermal desorption method is employed. Therefore, this sampling device is useful for determining the time-weighted average concentrations of organic solvent vapor in a working environment.
منابع مشابه
The Analysis of Ozone Precursors by AutoGC: The Role of Calibration and Quality Control Strategies in Data Management for Fully Automated Thermal Desorption-GC- FID Systems
The analysis of ozone precursors has been a feature of the EPA air quality surveillance regulations since 1992 with the establishment of Photochemical Assessment Monitoring Stations (PAMS) as part of State Implementation Plans (SIP) for ozone non-attainment areas classified as serious, severe or extreme. At that time, guidance documentation allowed for the measurements of VOC precursors either ...
متن کاملTrace determination of airborne polyfluorinated iodine alkanes using multisorbent thermal desorption/gas chromatography/high resolution mass spectrometry.
A novel gas chromatography/high resolution mass spectrometry method coupled with multisorbent thermal desorption cartridges has been developed for the determination of volatile neutral polyfluorinated iodine alkanes (PFIs) in airborne samples. It allows, for the first time, simultaneous analysis of four mono-iodized perfluorinated alkanes, three diiodized perfluorinated alkanes and four mono-io...
متن کاملA method for bubble volume measurement under constant flow conditions in gas–liquid two-phase flow
Measuring the volume of a bubble, especially at its detachment, is a basic subject in gas-liquid two-phase flow research. A new indirect method for this measurement under constant flow conditions is presented. An electronic device is designed and constructed based on laser beam intensity. This device calculates the frequency of the bubble formation by measuring the total time of the formation p...
متن کاملSample Preparation of Volatile Organic Compounds with Needle−Type Extraction Device
Quantification of volatile organic compounds (VOCs) in environmental air has been recently focused because of their adverse effects on human health, including the so−called multiple chemical sensitivity and sick building syndrome [1,2]. To investigate the effect of VOCs on human health and prevent the above illnesses, a sensitive and reliable method for determining the VOCs in air samples is de...
متن کاملMeasurement & Monitoring: 18th Quarterly Literature Update
24-Hour Diffusive Sampling of 1,3-Butadiene in Air onto Carbopack X Solid Adsorbent Followed by Thermal Desorption/GC/MS Analysis: Feasibility Study McClenny, W.A., D.A. Whitaker, K.D. Oliver, H.H. Jacumin Jr., and E.H. Daughtrey Jr. Symposium on Air Quality Measurement Methods and Technology, Research Triangle Park, NC, April 20-22, 2004 [EPA 600-04-062; NTIS PB2004-106812] Diffusive sampling ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Industrial health
دوره 33 4 شماره
صفحات -
تاریخ انتشار 1995