Reproducibility and day time bias correction of optoelectronic leg volumetry: a prospective cohort study

نویسندگان

  • Rolf P Engelberger
  • Claudia Blazek
  • Felix Amsler
  • Hong H Keo
  • Frédéric Baumann
  • Werner Blättler
  • Iris Baumgartner
  • Torsten Willenberg
چکیده

BACKGROUND Leg edema is a common manifestation of various underlying pathologies. Reliable measurement tools are required to quantify edema and monitor therapeutic interventions. Aim of the present work was to investigate the reproducibility of optoelectronic leg volumetry over 3 weeks' time period and to eliminate daytime related within-individual variability. METHODS Optoelectronic leg volumetry was performed in 63 hairdressers (mean age 45 ± 16 years, 85.7% female) in standing position twice within a minute for each leg and repeated after 3 weeks. Both lower leg (legBD) and whole limb (limbBF) volumetry were analysed. Reproducibility was expressed as analytical and within-individual coefficients of variance (CVA, CVW), and as intra-class correlation coefficients (ICC). RESULTS A total of 492 leg volume measurements were analysed. Both legBD and limbBF volumetry were highly reproducible with CVA of 0.5% and 0.7%, respectively. Within-individual reproducibility of legBD and limbBF volumetry over a three weeks' period was high (CVW 1.3% for both; ICC 0.99 for both). At both visits, the second measurement revealed a significantly higher volume compared to the first measurement with a mean increase of 7.3 ml ± 14.1 (0.33% ± 0.58%) for legBD and 30.1 ml ± 48.5 ml (0.52% ± 0.79%) for limbBF volume. A significant linear correlation between absolute and relative leg volume differences and the difference of exact day time of measurement between the two study visits was found (P < .001). A therefore determined time-correction formula permitted further improvement of CVW. CONCLUSIONS Leg volume changes can be reliably assessed by optoelectronic leg volumetry at a single time point and over a 3 weeks' time period. However, volumetry results are biased by orthostatic and daytime-related volume changes. The bias for day-time related volume changes can be minimized by a time-correction formula.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Author's response to reviews Title: Reproducibility and day time bias correction of optoelectronic leg volumetry: a prospective cohort study Authors:

This should be identical in the manuscript and the submission system The abstract in the submission system has been updated accordingly. Ethical approval: Any experimental research that is reported in the manuscript should have been performed with the approval of an appropriate ethics committee. The statement to this effect must include the name of the body which gave approval, with a reference...

متن کامل

P-219: Premature Progesterone Rise (PPR) At HCG Triggering Day Has No Correlation with ICSI Outcome: A Prospective Cohort Study

Background: The objective of this study is to evaluate the progesterone level (P Level) on the day of HCG triggering in GnRh agonist and antagonist protocols, and its correlation with clinical pregnancy rate and miscarriage rate. Premature luteinization during in vitro fertilization (IVF) was commonly happened before the introduction of GnRh analogues. High level of unwanted progesterone that i...

متن کامل

Reliability and limits of agreement of circumferential, water displacement, and optoelectronic volumetry in the measurement of upper limb lymphedema.

We conducted a reliability comparison study to determine the intrarater and inter-rater reliability and the limits of agreement of the volume estimated by circumferential measurements using the frustum sign method and the disk model method, by water displacement volumetry, and by infrared optoelectronic volumetry in the assessment of upper limb lymphedema. Thirty women with lymphedema following...

متن کامل

Embryo transfer in days 2 to 4 following intracytoplasmic sperm injection: a prospective cohort study

  Background: Improvement of assisted reproductive technique (ART) results in higher pregnancy rates from positive Beta HCG to take home baby statistics. Despite developments in culture media allowing blastocyst stage transfer, some centers apply second, third and sometimes fourth day post injection for embryo transfer. This study aimed to compare their reproductive outcomes.   Methods : This p...

متن کامل

Comparison of Double and Single Leg Weight-Bearing Radiography in Determining Knee Alignment

  Background: Knee malalignment is an important modifiable cause of osteoarthritis (OA). Surgical therapeutic procedures depend on proper knee alignment assessment. The purpose of this study was to compare knee alignment parameters between double and single leg weight-bearing radiographs and to evaluate the reproducibility of inter- and intra-observer measurements. Methods: One hundred eight p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2011