Non-invasive measurements of arterial structure and function: repeatability, interrelationships and trial sample size.
نویسندگان
چکیده
1. Repeatability of measurements of arterial compliance and flow-mediated dilation of the brachial artery has been infrequently reported, despite increasing use in interventional and risk-factor modification studies. Furthermore, little is known about the interrelationships of the various indices. The purposes of this study were to determine the repeatability and interrelationships of a range of arterial indices.2. Fifty healthy volunteers, 20 men and 30 women, aged 20-70 (mean 46.5) years, were studied on two occasions, using an identical protocol, at a mean interval of 2.5 weeks. Tonometry, ultrasound and Doppler technique were used to measure the following: carotid wall intima-media thickness (IMT), total systemic artery compliance (SAC), arterial pulse wave velocity [PWV aorto-femoral (A-F), and femoral-dorsalis pedis (F-D)], carotid distensibility coefficient (DC) and carotid augmentation index (AI). Brachial flow-mediated dilation was measured in 30 subjects with analysis of diameter change for 4 min post ischaemia.3. There were no systematic differences over the observed range of measurements for any of the reported parameters. Coefficients of variation were as follows: IMT 2.8%, SAC 9.2%, PWV(A-F) 3.2%, PWV(F-D) 5.0%, DC 10.0%, AI 1.3%. Brachial flow-mediated dilation curves were not different between visits; changes were maximum 60-s post ischaemia. All indices of arterial compliance were significantly correlated with age. The three different indices of central arterial compliance [SAC, PWV(A-F) and AI] were significantly correlated with carotid intima-media thickness.4. Under controlled experimental conditions there was good repeatability of measurements of indices between sessions of both intrinsic and functional arterial mechanical properties (central and carotid arterial compliance, intima-media thickness and brachial flow-mediated dilation). Sample size tables for clinical trials using these indices are presented.
منابع مشابه
Noninvasive measurements of arterial stiffness: Repeatability and interrelationships with endothelial function and arterial morphology measures
BACKGROUND Many noninvasive arterial assessment techniques have been developed, measuring different parameters of arterial stiffness and endothelial function. However, there is little data available comparing different devices within the same subject. Therefore, the purpose of this study was to examine the repeatability and interrelationships between 3 different techniques to measure arterial s...
متن کاملPresentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall
Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the substitution of the blood pressure changes in the central arteries such as carotid with the blood pressure changes in the brachial results in error in the blood...
متن کاملComparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study
Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...
متن کاملمقایسه دی اکسیدکربن انتهای بازدمی و شریانی در بیماران کاندید پیوند عروق کرونر
Background: Measuring end tidal carbon dioxide (ETCo2) is one of the methods used for estimating arterial carbon dioxide (PaCo2) during general anesthesia. ETCo2 measurements maybe obviate the need for repeating arterial puncture for determination of arterial PaCo2. This study performed to determine the accuracy of ETCo2 levels as a measure of PaCo2 levels in patients undergoing coronary artery...
متن کاملAutonomous Drug-Encapsulated Nanoparticles: Towards a Novel Non-Invasive Approach to Prevent Atherosclerosis
Introduction This paper proposes the concept of autonomous drug-encapsulated nanoparticle (ADENP) as a novel non-invasive approach to prevent atherosclerosis. ADENP consists of three simple units of sensor, controller (computing), and actuator. The hardware complexity of ADENP is much lower than most of the nanorobots, while the performance is maintained by the synergism in the swarm architectu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical science
دوره 95 6 شماره
صفحات -
تاریخ انتشار 1998