SPECT Imaging of 2-D and 3-D Distributed Sources with Near-Field Coded Aperture Collimation: Computer Simulation and Real Data Validation.

نویسندگان

  • Zhiping Mu
  • Lawrence W Dobrucki
  • Yi-Hwa Liu
چکیده

The imaging of distributed sources with near-field coded aperture (CA) remains extremely challenging and is broadly considered unsuitable for single-photon emission computerized tomography (SPECT). This study proposes a novel CA SPECT reconstruction approach and evaluates the feasibilities of imaging and reconstructing distributed hot sources and cold lesions using near-field CA collimation and iterative image reconstruction. Computer simulations were designed to compare CA and pinhole collimations in two-dimensional radionuclide imaging. Digital phantoms were created and CA images of the phantoms were reconstructed using maximum likelihood expectation maximization (MLEM). Errors and the contrast-to-noise ratio (CNR) were calculated and image resolution was evaluated. An ex vivo rat heart with myocardial infarction was imaged using a micro-SPECT system equipped with a custom-made CA module and a commercial 5-pinhole collimator. Rat CA images were reconstructed via the three-dimensional (3-D) MLEM algorithm developed for CA SPECT with and without correction for a large projection angle, and 5-pinhole images were reconstructed using the commercial software provided by the SPECT system. Phantom images of CA were markedly improved in terms of image quality, quantitative root-mean-squared error, and CNR, as compared to pinhole images. CA and pinhole images yielded similar image resolution, while CA collimation resulted in fewer noise artifacts. CA and pinhole images of the rat heart were well reconstructed and the myocardial perfusion defects could be clearly discerned from 3-D CA and 5-pinhole SPECT images, whereas 5-pinhole SPECT images suffered from severe noise artifacts. Image contrast of CA SPECT was further improved after correction for the large projection angle used in the rat heart imaging. The computer simulations and small-animal imaging study presented herein indicate that the proposed 3-D CA SPECT imaging and reconstruction approaches worked reasonably well, demonstrating the feasibilities of achieving high sensitivity and high resolution SPECT using near-field CA collimation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimizing wide-field coded aperture imaging: radial mask holes and scanning

Imaging at hard X-ray energies (~10-600 keV) over very large fields of view (~60 per telescope) is required to conduct a high sensitivity all-sky and all-time survey for black holes. The proposed Energetic X-ray Imaging Survey Telescope (EXIST) could achieve the high sensitivity required for the mission science objectives by scanning an array of wide-field coded aperture telescopes with apertur...

متن کامل

High-resolution, high sensitivity detectors for molecular imaging with radionuclides: The coded aperture option

Molecular imaging with radionuclides is a very sensitive technique because it allows to obtain images with nanomolar or picomolar concentrations. This has generated a rapid growth of interest in radionuclide imaging of small animals. Indeed radiolabeling of small molecules, antibodies, peptides and probes for gene expression enables molecular imaging in vivo, but only if a suitable imaging syst...

متن کامل

Basic design and simulation of a SPECT microscope for in vivo stem cell imaging

The need to understand the behavior of individual stem cells at the various stages of their differentiation and to assess the resulting reparative action in pre-clinical model systems, which typically involves laboratory animals, provides the motivation for imaging of stem cells in vivo at high resolution. Our initial focus is to image cells and cellular events at single cell resolution in vivo...

متن کامل

Improving 3-D Imaging Breast Cancer Diagnosis Systems Using a New Method for Placement of Near-Infrared Sources and Detectors

The objective of this research was to improve 3-D imaging system by near-infrared light emission in breast tissue to achieve a more accurate diagnosis of tumor. The results of repeated experiments in this research have shown that with this imaging system, a more accurate diagnosis of abnormal area depends on the location of the sources and detectors. Therefore, an optimal location model has bee...

متن کامل

Design of Near-field Coded Aperture Cameras for High-resolution Medical and Industrial Gamma-ray Imaging

Coded Aperture Imaging is a technique originally developed for X-ray astronomy, where typical imaging problems are characterized by far-field geometry and an object made of point sources distributed over a mainly dark background. These conditions provide, respectively, the basis of artifact-free and high Signal-to-Noise Ratio (SNR) imaging. When the coded apertures successful in far-field probl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of medical and biological engineering

دوره 36  شماره 

صفحات  -

تاریخ انتشار 2016