Seroepidemiological study after a long-distance industrial outbreak of legionnaires' disease.
نویسندگان
چکیده
Following a long-distance outbreak of Legionnaires' disease from an industrial air scrubber in Norway in 2005, a seroepidemiological study measuring levels of immunoglobulin G (IgG) and IgM antibodies to Legionella pneumophila was performed with a polyvalent enzyme-linked immunosorbent assay. One year after the outbreak, IgG levels in employees (n = 213) at the industrial plant harboring the scrubber and in blood donors (n = 398) from the outbreak county were low but significantly higher (P < or = 0.002) than those in blood donors (n = 406) from a nonexposed county. No differences in IgM levels among the three groups were found after adjustment for gender and age. Home addresses of the seroresponders in the exposed county clustered to the city of the outbreak, in contrast to the scattering of addresses of the seroresponding donors in the nonexposed county. Factory employees who operated at an open biological treatment plant had significantly higher IgG and IgM levels (P < or = 0.034) than those working >200 m away. Most of the healthy seroresponders among the factory employees worked near this exposure source. Immunoblotting showed that IgG and IgM antibodies in 82.1% of all seroresponders were directed to the lipopolysaccharide of the L. pneumophila serogroup 1 outbreak strain. In conclusion, 1 year after the long-distance industrial outbreak a small increase in IgG levels of the exposed population was observed. The open biological treatment plant within the industrial premises, however, constituted a short-distance exposure source of L. pneumophila for factory employees working nearby.
منابع مشابه
Proximity of the home to a cooling tower and risk of non-outbreak Legionnaires' disease.
OBJECTIVE To study the source of non-outbreak legionnaires' disease, particularly the role of cooling towers, by comparing the locations of patients' homes in relation to the location of cooling towers. DESIGN Retrospective, descriptive study of a case series of patients with legionnaires' disease ill between 1978 and 1986 and, for comparison, a case series of patients with lung cancer. A pro...
متن کاملOutbreak of legionnaires' disease from a cooling water system in a power station.
In September and October 1981 six cases of pneumonia occurred among men working in a power station under construction. Three were identified as cases of legionella pneumonia and two others had serology suggestive of legionella infection. In a sample of 92 men from the site 10 had low levels of antibodies to legionella; a similar sample of men working on an adjacent site showed none with positiv...
متن کاملEpidemiological investigation and case-control study: a Legionnaires' disease outbreak associated with cooling towers in Warstein, Germany, August-September 2013.
Between 1 August and 6 September 2013, an outbreak of Legionnaires' disease (LD) with 159 suspected cases occurred in Warstein, North Rhine-Westphalia, Germany. The outbreak consisted of 78 laboratory-confirmed cases of LD, including one fatality, with a case fatality rate of 1%. Legionella pneumophila, serogroup 1, subtype Knoxville, sequence type 345, was identified as the epidemic strain. A ...
متن کاملA large community outbreak of Legionnaires disease in Vila Franca de Xira, Portugal, October to November 2014.
An outbreak of Legionnaires’ disease with 334 confirmed cases was identified on 7 November 2014 in Vila Franca de Xira, Portugal and declared controlled by 21 November. Epidemiological, environmental and microbiological analysis identified industrial wet cooling systems to be the probable source of infection. Preliminary results from sequence-based typing of clinical specimens and environmental...
متن کاملLegionnaires' disease outbreak: Victoria's largest identified outbreak.
This paper describes and analyses some aspects of an outbreak of Legionnaires' disease in Victoria, commencing in late October 1998. In all, 18 cases caused by Legionella pneumophila serogroup 1 were notified within 10 days making this the largest outbreak in Victoria reported to that date. All cases had epidemiological links to an industrial estate in a northern Melbourne suburb. Extensive env...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical and vaccine immunology : CVI
دوره 16 4 شماره
صفحات -
تاریخ انتشار 2009