Comparison of two planning systems for HDR brachytherapy gynecological application

نویسندگان

  • Osman A. Elhanafy
  • Mostafa D. Migahed
  • Hanim A. Sakr
  • Mostafa Ellithy
  • Rupak K. Das
  • Heath J. Odau
  • Bruce R. Thomadsen
چکیده

PURPOSE This report compares the Nucletron NPS and PLATO planning system for patients treated for cervix cancer. MATERIALS AND METHODS This study compares calculations generated using the older NPS (version 11.43) planning system and the more recent PLATO (version 14.1) system for two cases: 1) a single dwell position and 2) an actual patient application using a tandem and ovoid. RESULTS For one dwell position: for NPS planning the dose for points along the source axis forward of the cable was 9.85% more than for symmetrically placed points in the cable direction. For PLATO, the same test gave rise to a difference of 10.2%. Comparing the two systems, NPS calculated doses for points in the forward direction 14% greater than those calculated by PLATO. The entry of points using the digitizer accounted for less than 1% of any difference. For the patient case: the dose difference between NPS and PLATO planning for all patient reference points entered from films ranged from 1 to 4%. The difference in dose between optimized and nonoptimized planning was approximately 0.5% for prescription points (points A), while for the bladder and rectum the differences were 6% and 20%, respectively with NPS, and with PLATO, 8% and 22%, respectively. CONCLUSION This study highlighted the effects of the differences in the calculational algorithm between the older and newer planning systems from Nucletron. While the differences were minimal on the perpendicular bisector of the source, along the axis they become considerable. In a practical gynecological case, these differences mostly affect the dose to the rectum, since that organ receives the greatest proportion of its dose from rays near the same axis. Overall, the PLATO system plan required about 2.5% less integrated reference air kerma than the NPS plan for the same dose to point A. For either planning system, optimization is crucial in decreasing dose to bladder and rectal points.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Implementation of a Complementary Treatment Planning Software for the GZP6 HDR Brachytherapy System (GZP6 CTPS)

Introduction: Brachytherapy is one of the most common treatment modalities for gynecological cancer. The GZP6 brachytherapy system is one of the devices utilized in Iran. It has been considered particularly due to its low cost compared to other more complete and established systems. This system has some deficiencies including lack of a treatment planning software for non-predefined treatments, ...

متن کامل

ارزیابی اثر ناهمگنی هوا در محاسبات دوز براکی تراپی HDR نای توسط فیلم EDR2

Background and purpose: Dose calculations in trachea HDR brachytherapy treatment planning systems are greatly based on TG-43 protocol in which, all materials including air inside trachea are treated the same as water. The aim of this study was to survey the effect of air on dose calculations of Flexiplan treatment planning system in trachea HDR brachytherapy. Materials and methods: To ev...

متن کامل

Developing a Verification and Training Phantom for Gynecological Brachytherapy System

Introduction Dosimetric accuracy is a major issue in the quality assurance (QA) program for treatment planning systems (TPS). An important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. In brachytherapy (BT) of gynecological (Gyn) cancer it is usual to insert a combination of tandem and ovoid applicators with a complicat...

متن کامل

Evaluation of deformable image registration in HDR gynecological brachytherapy

Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from I...

متن کامل

Monte Carlo investigation on precise dosimetry of HDR breast brachytherapy with Accuboost

Introduction: Accuboost is a HDR brachytherapy system in early stages breast cancer treatment. This device provides a completely noninvasive procedure with parallel-opposed radiation from two immobilizing peripheral applicators that caused it a preferred option of modalities to choose. In most commercial treatment planning systems, tissues are considered as a simple water phan...

متن کامل

Rectal and Bladder Dose Measurements in the Intracavitary Applications of Cervical Cancer Treatment with HDR Afterloading System: Comparison of TPS Data with MOSFET Detector

Background: Intracavitary brachytherapy plays a major role in management of cervical carcinoma. Assessment of dose received by OAR’s therefore becomes crucial for the estimation of radiation toxicities in HDR brachytherapy. Objective: Purpose of this study is to evaluate the role of in vivo dosimetry in HDR brachytherapy and to compare actual doses delivered to OAR’ s with those calculate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2001