Hemodynamic Assessment of a Murine Heterotopic Biventricularly Loaded Cardiac Transplant in vivo Model.
نویسندگان
چکیده
BACKGROUND Heterotopic heart transplantation (HHT) in rodent animal models represents an important technique enabling studies on organ transplantation immunology and pharmaceutical development. Recent investigations used nonworking HHT designs, with the left ventricle (LV) bypassed in the anastomosis system. In spite of their principal success, the lack of orthogonal ventricular filling leads to myocardial atrophy. However, when focusing on the cellular and molecular mechanisms involved in the in vivo remodeling of the myocardium or cell-based cardiovascular implants, a nonworking model is suboptimal as it lacks the native-analogous hemodynamic and metabolic situation. Here we present the hemodynamic and electrical assessment of a biventricularly loaded murine HHT method without the need for a combined heart-lung transplantation approach. METHODS Heterotopic transplantations (n = 13) were performed on C57BL/6J-(H-2b) inbred mice (n = 13 donors, n = 13 recipients) by creating end-to-side anastomoses between the donors' cranial vena cava (CrVC) and the recipients' abdominal caudal vena cava (CVC), between the donors' ascending aorta and the recipients' abdominal aorta (aAo), and between the grafts' pulmonary trunk and the left atrium. After transplantation, a hemodynamic assessment using echocardiography (including 2D speckle tracking analysis) and electrocardiography was performed. RESULTS The loaded HHT procedure in the mice was performed with an overall success rate of 61%. In 3 of the remaining 5 cases, only atrial function was restored. The median duration of the entire surgical procedure for the recipient animal was 190 (IQR 180-250) min. The mean heart rate in the loaded HHT group was 355 ± 6 bpm in comparison to the control group with an in situ heart rate of 418 ± 61 bpm. A native-like closing and opening pattern of the aortic and mitral valves (visible on both 2D and M-mode images) was observed, confirming a native-analogous loading of the LV. Pulsed-wave Doppler provided visualization of the flow across the region of anastomoses between the pulmonary trunk and the left atrium, reaching a mean maximum velocity of 382 ± 12 mm/s. Exemplary 2D speckle tracking analysis of the LV free wall and interventricular septum revealed some differences in vector directions in one animal when compared to the orthotopic native heart, indicating an asynchronous movement of the LV. CONCLUSIONS These results demonstrate the technical (micro)surgical feasibility of a fully loaded HHT procedure in the murine model without using a combined heart-lung transplantation approach. The acute hemodynamic performance of the HHT grafts approximated the native orthotopic situation. This model may open up new options for the investigation of cellular and molecular questions in the murine cardiovascular in vivo system in the near future.
منابع مشابه
The impact of physiological loading on immune cell infiltration and myocardial function evaluated by cardiac MRI: a comparison between non-working heart and working heart transplant models
Rodent models of heterotopic cardiac transplantation are important for gaining a better understanding of heart allograft rejection. This study compared a working heart (WkHt) transplant model, which have developed by our laboratory, with the traditional non-working heart (Non-WkHt) model using cardiac MRI (CMRI) and pathological evaluation. Our results indicate that the physiological hemodynami...
متن کاملHemodynamic and metabolic effects of paced linkage following heterotopic cardiac transplantation.
BACKGROUND AND PURPOSE Heterotopic cardiac transplantation is a valuable surgical technique that maximizes the use of donor organs. However, recipient heart function may decline steadily postoperatively with resulting clinical deterioration. Paced linkage has the potential of reducing afterload and enhancing coronary flow of both hearts, thereby improving recipient- and donor-heart function. Th...
متن کاملVarying Degrees of Ventricular Unloading in the Heterotopic Rat Heart Transplant Model Demonstrated by Magnetic Resonance Imaging
OBJECTIVE Left ventricular assist device placement is an increasingly common treatment for cardiac failure, resulting in cardiac unloading and potentially reversing the remodelling changes seen in heart failure. A popular animal model for human ventricular unloading is the rodent heterotopic non-working heart transplant; the volume loading status of this preparation is important to interpreting...
متن کاملHeterotopic cardiac transplantation decreases the capacity for rat myocardial protein synthesis.
Heterotopic cardiac isografts are vascularly perfused hearts that maintain structural and functional integrity for prolonged periods of time. When placed in an infrarenal location, the heart is hemodynamically unloaded and undergoes negative growth, leading to cardiac atrophy. At 7 and 14 days after transplantation, the transplanted heart was decreased in size compared with the in situ heart (p...
متن کاملRat Heterotopic Abdominal Heart/Single-lung Transplantation in a Volume-loaded Configuration.
Herein, we describe a novel technique for heterotopic abdominal heart-lung transplantation (HAHLT) in rats. The configuration of the transplant graft involves anastomosis of donor inferior vena cava (IVC) to recipient IVC, and donor ascending aorta (Ao) to recipient abdominal Ao. The right upper and middle lung lobes are preserved and function as conduits for blood flow from right heart to left...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European surgical research. Europaische chirurgische Forschung. Recherches chirurgicales europeennes
دوره 57 3-4 شماره
صفحات -
تاریخ انتشار 2016