NIST Reference Spectroradiometer for Color Display Calibrations
نویسندگان
چکیده
A program to develop calibration services for colormeasuring instruments has been established recently at the National Institute of Standards and Technology (NIST) to address commercial and industrial needs for higher-accuracy measurements of displays. In particular, a reference spectroradiometer has been built with the goal of enabling measurements of displays with the smallest possible uncertainty. The instrument has been characterized for wavelength error, variable bandpass, stray light, linearity and random noise. The accuracy of color measurements with this instrument has been assessed using detailed simulations incorporating the measured performance characteristics of the instrument. In the simulations, the uncertainty in color measurements of sixteen CRT and LCD display colors was calculated. The results of the simulations imply that the instrument is capable of measuring colors of displays with a combined standard uncertainty of approximately 0.001 in chromaticity (x,y) and 1 % in luminance (Y ).
منابع مشابه
New Photometric Calibration Programs at the National Institute of Standards and Technology
The NIST candela is maintained via standard photometers which have shown long-term stability better than 0.1% per year. The detector-based method has allowed us to reduce the uncertainties of calibrations and to expand the range of calibration capabilities. There have been several new developments in photometry at NIST. A high-illuminance calibration facility has been developed. Four temperatur...
متن کاملNew photometric calibration programmes at the National Institute of Standards and Technology
The National Institute of Standards and Technology (NIST) candela is maintained via standard photometers which have shown long-term stability of better than 0.1 % per year. The detector-based method has allowed us to reduce the uncertainties of calibrations and to expand the range of calibration capabilities. There have been several new developments in photometry at the NIST. A high-illuminance...
متن کاملIrradiance of Horizontal Quartz-Halogen Standard Lamps
Spectral irradiance calibrations often require that irradiance standard lamps be oriented differently than the normal calibration orientation used at the National Institute of Standards and Technology and at other standards laboratories. For example, in solar measurements the instruments are generally upward viewing, requiring horizontal working standards for minimization of irradiance calibrat...
متن کاملNIST Colorimetric Calibration Facility for Displays − Part 2
Development of a calibration facility for spectroradiometric, colorimetric, and goniometric measurements of displays, display colorimeters, and spectroradiometers has been completed at the National Institute of Standards and Technology (NIST). An overview of the facility and results of the characterization measurements are presented. The results show that the facility is capable of measuring co...
متن کاملIlluminance Responsivity Calibration of Reference Photometers at the Nist Sircus and Scf Facilities
The illuminance responsivities of two transfer standard photometers have been directly determined from their spectral responsivity calibrations at two different calibration facilities of NIST. The main characteristics of the two photometers, and their calibrations are described. The spectral and broad-band (illuminance) responsivities measured at the two different facilities are compared. The t...
متن کامل