Preclinical evaluation of the thrombogenicity and endothelialization of bare metal and surface-coated neurovascular stents.

نویسندگان

  • S Krajewski
  • B Neumann
  • J Kurz
  • N Perle
  • M Avci-Adali
  • G Cattaneo
  • H P Wendel
چکیده

BACKGROUND AND PURPOSE Stent-assisted coiling is routinely used for the endovascular treatment of complex or wide-neck intracranial aneurysms. However, in-stent thrombosis, thromboembolic events, and ischemic complications remain a major concern associated with stent implants. Therefore, a novel low-profile neurovascular stent with a bare metal surface was investigated with regard to thrombogenicity and endothelialization and compared with the same stent coated with albumin or heparin. MATERIALS AND METHODS The bare metal and heparin- or albumin-coated stents were loaded in heparin-coated tubing, which was then filled with heparinized human blood (n = 5) and circulated at 150 mL/min and 37°C for 60 minutes. Before and after circulation, measurement of various inflammation and coagulation markers and scanning electron microscopy were performed. Endothelialization of the stents was investigated in an in vitro model including human umbilical vascular endothelial cells. RESULTS Our results showed that platelet loss and platelet activation and activation of the coagulation cascade, which are induced by the bare metal stents, were significantly reduced by heparin or albumin coating. Adverse effects on erythrocytes, leukocytes, and the complement cascade were not induced by the bare metal or coated stents. Moreover, the bare metal and albumin-coated stents showed good endothelialization properties. CONCLUSIONS Albumin and heparin coatings clearly improve the thrombogenicity of the stents and thus may represent fundamental progress in the treatment of intracranial aneurysms. Moreover, preclinical evaluation of neurovascular stents under physiologic conditions supports and accelerates the development of more biocompatible neurovascular stents.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thrombogenicity and early vascular healing response in metallic biodegradable polymer-based and fully bioabsorbable drug-eluting stents.

BACKGROUND Acute thrombogenicity and re-endothelialization represent clinically relevant end points pertaining to the safety of coronary stents, which have not been compared among biodegradable polymer-based drug-eluting metallic stents and fully bioabsorbable scaffolds to date. METHODS AND RESULTS We investigated comparative outcomes with respect to acute thrombogenicity and re-endothelializ...

متن کامل

The impact of vascular endothelial growth factor-transfected human endothelial cells on endothelialization and restenosis of stainless steel stents.

OBJECTIVES The purpose of this study was to investigate the effects of gene transfection of endothelial cells with vascular endothelial growth factor (VEGF) on re-endothelialization and inhibiting in-stent restenosis. METHODS Stents coated with human umbilical vein endothelial cells (HUVECs) transfected with VEGF(121) were studied both in vitro and in vivo. In vitro studies were performed usi...

متن کامل

Accelerating endothelialization of coronary stents by capturing circulating endothelial progenitor cells

Drug-eluting stents (DES) have become the standard of care for the treatment of coronary artery disease. However, late stent thrombosis has emerged as a major concern, especially in ‘off-label’ use. Pathologic studies of patients dying from late DES thrombosis demonstrate delayed arterial healing, characterized by persistent fibrin deposition and poor endothelialization. In recent years, a nove...

متن کامل

Everolimus-eluting stents improve vascular response in a diabetic animal model.

BACKGROUND Preclinical evaluation of the vascular response of drug-eluting stents is limited especially in the setting of diabetes mellitus preventing the evaluation of changes in drug-eluting stent design and eluted drugs after clinical use. METHODS AND RESULTS Cultured human aortic endothelial cells were used to assess the differences between sirolimus and its analog, everolimus, in the set...

متن کامل

Targeting In-Stent-Stenosis with RGD- and CXCL1-Coated Mini-Stents in Mice

Atherosclerotic lesions that critically narrow the artery can necessitate an angioplasty and stent implantation. Long-term therapeutic effects, however, are limited by excessive arterial remodeling. We here employed a miniaturized nitinol-stent coated with star-shaped polyethylenglycole (star-PEG), and evaluated its bio-functionalization with RGD and CXCL1 for improving in-stent stenosis after ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 36 1  شماره 

صفحات  -

تاریخ انتشار 2015