Acceptance, Commissioning and Field Testing

نویسندگان

  • Michael Obrist
  • Stephan Gerspach
  • Klaus-Peter Brand
چکیده

The introduction of the standard IEC 61850 for communication in power systems enables to build enhanced Substation Automation (SA) systems and to distribute requested functionalities in an optimal and standardized way. This brings new challenges and opportunities related to interoperability between compliant IEDs and tools as well as for testing and maintenance processes. The complete sequence of testing from products to systems is summarized and the impact of IEC 61850 to these tests is given.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effective commissioning of bus bar protection systems using a dynamic simulation in the field

Comprehensive testing of a bus bar protection system during commissioning or factory acceptance tests has always been a quite challenging and exhaustive task. Using a dynamic simulation software which directly controls multiple conventional test sets for simultaneous injection of test currents into all bay units is very efficient, since it does not require any rewiring all the time. Within the ...

متن کامل

Commissioning and acceptance testing of a CyberKnife linear accelerator

Acceptance testing and commissioning of a CyberKnife robotic stereotactic radiosurgery system was performed in April 2006. The CyberKnife linear accelerator produces a photon beam of 6 MV nominal energy, without the use of a flattening filter. Clinically measured tissue-phantom ratios, off-center ratios, and output factors are presented and compared with similar data from other CyberKnife sites...

متن کامل

Virtual commissioning of process automation software in drinking water treatment plants

In industry, the traditional factory acceptance test (FAT) of process automation (PA) software is being replaced by virtual commissioning (VC). In this paper VC is introduced in drinking water treatment. A quantitative measure has been defined to compare the shortenings of time-to-market of projects tested with VC and FAT, while taking into account the size and complexity of the software. The m...

متن کامل

The comparison between 6 MV Primus LINAC simulation output using EGSnrc and commissioning data

Introduction: Monte Carlo calculation method is considered to be the most accurate method for dose calculation in radiotherapy. The purpose of this research is comparison between 6 MV Primus LINAC simulation output with commissioning data using EGSnrc and build a Monte Carlo geometry of 6 MV Primus LINAC as realistically as possible. The BEAMnrc and DOSXYZnrc (EGSnrc package) M...

متن کامل

Commissioning the First Mobile Dedicated Accelerator for Intraoperative Electron Radiotherapy in Iran

Introduction: Intraoperative radiotherapy is a radiotherapy technique in which a high single fraction of radiation dose is delivered to the patient after surgery and Concurrent with anesthesia time. The most frequent method for IORT implementation is Intraoperative electron radiotherapy (IOERT), in which, some dedicated and high dose per pulse electron accelerators are employe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013