Mechanism of action of the tetraflex accommodative intraocular lens.
نویسندگان
چکیده
PURPOSE To investigate the mechanism of action of the Tetraflex (Lenstec Kellen KH-3500) accommodative intraocular lens (IOL). METHODS Thirteen eyes of eight patients implanted with the Tetraflex accommodating IOL for at least 2 years underwent assessment of their objective amplitude-of-accommodation by autorefraction, anterior chamber depth and pupil size with optical coherence tomography, and IOL flexure with aberrometry, each viewing a target at 0.0 to 4.00 diopters of accommodative demand. RESULTS Pupil size decreased by 0.62 ± 0.41 mm on increasing accommodative demand, but the Tetraflex IOL was relatively fixed in position within the eye. The ocular aberrations of the eye changed with increased accommodative demand, but not in a consistent manner among individuals. Those aberrations that appeared to be most affected were defocus, vertical primary and secondary astigmatism, vertical coma, horizontal and vertical primary and secondary trefoil, and spherical aberration. CONCLUSIONS Some of the reported near vision benefits of the Tetraflex accommodating IOL appear to be due to changes in the optical aberrations because of the flexure of the IOL on accommodative effort rather than forward movement within the capsular bag.
منابع مشابه
Near Visual Performance Results of the Accommodating Intraocular Lens (Tetraflex)® in Comparison to Monofocal Foldable Intraocular Lens
Purpose: To evaluate the near visual performance of an accommodative intraocular lens (IOL); Tetraflex, in comparison to a standard monofocal foldable IOL in cataract surgery. Setting: Eye Research Center, Farabi Eye Hospital, Department of Ophthalmology, Tehran University of Medical Sciences, Iran. Methods: Forty six eyes of 23 patients with cataract underwent phacoemulsification and accommoda...
متن کاملUS FDA clinical trial of the Tetraflex potentially accommodating IOL: comparison to concurrent age-matched monofocal controls.
PURPOSE To assess the efficacy of the Tetraflex (Lenstec Inc) intraocular lens (IOL) to provide enhanced near reading ability and spectacle independence relative to a monofocal control IOL in bilaterally implanted eyes tested binocularly. METHODS A prospective, age-matched, non-randomized US Food and Drug Administration clinical trial of 255 Tetraflex and 101 monofocal IOL control patients wa...
متن کاملPotential of the 1 CU accommodative intraocular lens.
AIM To assess the accommodative power of a new foldable monofocal intraocular lens. METHOD A prospective randomised non-masked clinical interventional study. The study included 40 patients attending the hospital for cataract surgery and who were randomly distributed into a study group receiving a new foldable monofocal intraocular lens with flexible haptics, and a control group receiving a st...
متن کاملAccommodative intraocular lenses for age-related cataracts.
The standard intraocular lens (IOL) that is used to replace a cataractous lens cannot change focus from distant to near objects, so most patients need glasses for near vision after cataract surgery. Limited evidence suggests that accommodative IOLs provide better near vision than monofocal IOLs, but not better than multifocal IOLs. Long-term follow-up is needed to confirm patient outcomes, and ...
متن کاملReal and Pseudoaccommodation in Accommodative Lenses
In the attempt to manage presbyopia, different intraocular lens designs have been proposed such as monofocal IOLs with monovision or multifocal IOLs. Even though the lenses mentioned offer satisfactory visual results, contemporary ophthalmology has not completely answered the presbyopic dilemma by simulating the accommodative properties of the crystalline lens itself. Accommodative IOLs were de...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of refractive surgery
دوره 26 11 شماره
صفحات -
تاریخ انتشار 2010