Certification of NIST Room Temperature Low-Energy and High-Energy Charpy Verification Specimens.
نویسندگان
چکیده
The possibility for NIST to certify Charpy reference specimens for testing at room temperature (21 °C ± 1 °C) instead of -40 °C was investigated by performing 130 room-temperature tests from five low-energy and four high-energy lots of steel on the three master Charpy machines located in Boulder, CO. The statistical analyses performed show that in most cases the variability of results (i.e., the experimental scatter) is reduced when testing at room temperature. For eight out of the nine lots considered, the observed variability was lower at 21 °C than at -40 °C. The results of this study will allow NIST to satisfy requests for room-temperature Charpy verification specimens that have been received from customers for several years: testing at 21 °C removes from the verification process the operator's skill in transferring the specimen in a timely fashion from the cooling bath to the impact position, and puts the focus back on the machine performance. For NIST, it also reduces the time and cost for certifying new verification lots. For one of the low-energy lots tested with a C-shaped hammer, we experienced two specimens jamming, which yielded unusually high values of absorbed energy. For both specimens, the signs of jamming were clearly visible. For all the low-energy lots investigated, jamming is slightly more likely to occur at 21 °C than at -40 °C, since at room temperature low-energy samples tend to remain in the test area after impact rather than exiting in the opposite direction of the pendulum swing. In the evaluation of a verification set, any jammed specimen should be removed from the analyses.
منابع مشابه
Impact Toughness Modification of NIST Low-Energy Charpy Verification Specimens for Testing at Room Temperature
The possibility for the National Institute for Standards and Technology (NIST) to certify Charpy reference specimens for testing at room temperature (21 °C ± 1 °C) instead of −40 °C was investigated in a previous study, in which a slightly increased likelihood of specimen jamming was observed at the low-energy level (13 J to 20 J). Moreover, there is a concern that the higher impact toughness o...
متن کاملThe Effect of Microstructure on Estimation of the Fracture Toughness (KIC) Rotor Steel Using Charpy Absorbed Energy (CVN)
The proportional relationships between the Charpy absorbed energy (CVN) and the KIC values have been established for a wide variety of steels. Several formulae have been proposed that predict KIC from CVN. The purpose of this study is to investigate, by means of compact testing fracture toughness specimens, the effective role of microstructure for estimation of the fractur...
متن کاملCorrelation of Energy, Deformation and Fractographic Parameters of Microalloyed Steel Welded Joint Fracture
Toughness is a complex material characteristic that is viewed from multiple aspects and is influenced by numerous factors. It is very important to have ability to assess toughness, i.e. to determine ductile or brittle material behaviour at any specific time. Beside total impact energy obtained at Charpy instrumented pendulum, the use of additional parameters such as lateral extension measuremen...
متن کاملNumerical Crashworthiness Analysis of Graded Layered Foam- Filled Tubes Under Axial Loading
In this article, the results of a study on energy absorption characteristics of foam-filled thin-walled structures with finite element analysis have been presented. Four specimens of thin walled structures have been filled with uniform foam and three specimens have been filled with linear four-layered foam. Also, eight layers HLH (High-Low-High) and eight layers LHL (Low-High-Low) have been sim...
متن کاملCFD Modeling Study of High Temperature and Low Oxygen Content Exhaust Gases Combustion Furnaces
This paper reports a CFD modeling study on the possibility of using high temperature and low oxygen content exhaust gases as oxidant for combustion in an industrial furnace by a written computer program. Under these conditions,the predicted results for the flow and heat transfer properties are compared with those under the several cases of conventional and highly preheated...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of research of the National Institute of Standards and Technology
دوره 120 شماره
صفحات -
تاریخ انتشار 2015