Rapid protein digestion and identification using monolithic enzymatic microreactor coupled with nano-liquid chromatography-electrospray ionization mass spectrometry.
نویسندگان
چکیده
A novel monolithic enzymatic microreactor was prepared in the fused-silica capillary by in situ polymerization of acrylamide (AA), N-acryloxysuccinimide (NAS) and ethylene dimethacrylate (EDMA) in the presence of a binary porogenic mixture of dodecanol and cyclohexanol, which could offer very low back pressure, enabling the fast digestion of proteins. The performance of the monolithic microreactor was demonstrated by digesting cytochrome c at high flow rate, and the comparisons between the in-solution digestion and on-column reaction were made by a nano-high performance liquid chromatography-mass spectrometry (nano-HPLC-MS) system. The performance of the monolithic microreactor was demonstrated with the digestion of cytochrome c at the fast flow rate of 1 microL/min, which afforded a residence time of 7s, yielding a sequence coverage of 54.81% using strict multiple database searching thresholds. Future more, a mixture of four standard proteins was digested and analyzed using the on-line digestion and nano-HPLC-MS system. The results showed the promising of such a system in the analysis of protein mixture.
منابع مشابه
A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملA Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملRapid protein identification using monolithic enzymatic microreactor and LC-ESI-MS/MS.
A monolithic enzymatic microreactor was prepared in a fused-silica capillary by in situ polymerization of acrylamide, glycidyl methacrylate (GMA) and ethylene dimethacrylate (EDMA) in the presence of a binary porogenic mixture of dodecanol and cyclohexanol, followed by ammonia solution treatment, glutaraldehyde activation and trypsin modification. The choice of acrylamide as co-monomer was foun...
متن کاملProteolysis in microfluidic droplets: an approach to interface protein separation and peptide mass spectrometry.
A versatile microreactor protocol based on microfluidic droplets has been developed for on-line protein digestion. Proteins separated by liquid chromatography are fractionated in water-in-oil droplets and digested in sequence. The microfluidic reactor acts also as an electrospray ionization emitter for mass spectrometry analysis of the peptides produced in the individual droplets. Each droplet ...
متن کاملOnline integration of multiple sample pretreatment steps involving denaturation, reduction, and digestion with microflow reversed-phase liquid chromatography-electrospray ionization tandem mass spectrometry for high-throughput proteome profiling.
A facile integrated platform for proteome profiling was established, in which native proteins were online denatured and reduced within a heater, digested with an immobilized trypsin microreactor, and analyzed by microflow reversed-phase liquid chromatography with electrospray ionization tandem mass spectrometry (microRPLC-ESI-MS/MS). In comparison to the traditional off-line urea denaturation p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography. A
دوره 1106 1-2 شماره
صفحات -
تاریخ انتشار 2006