Evaluation of Five Different Desensitizers: A Comparative Dentin Permeability and SEM Investigation In Vitro

نویسندگان

  • Nasibe Aycan Yilmaz
  • Ertan Ertas
  • Hasan Orucoğlu
چکیده

BACKGROUND/OBJECTIVE The purpose of this study was to evaluate the efficacy and durability of five different dentin desensitizers (Gluma Desensitizer Powergel, Bifluorid 12, Gluma Self Etch Bond, D/Sense Crystal, Nupro Sensodyne Prophylaxis Paste with Novamin) on tubule occlusion and dentin permeability reduction in vitro. METHOD The quantitative changes in permeability of 100 dentin discs were measured after desensitizer treatments and following post-treatments of 6% citric acid challenge for 1 min or immersion in artificial saliva for 24 hours under hydrostatic pressure generated by a computerised fluid filtration meter. Qualitative SEM analyses were also carried out. RESULTS Dentin permeability decreased after desensitizer application in all groups. Nevertheless, only the difference between 'Gluma Self Etch Bond' and 'Nupro Sensodyne Prophylaxis Paste with Novamin' groups was significantly different (p<0.05). Dentin permeability increased significantly after post-treatments (p<0.05). There was no statistically difference among the citric acid-subgroups (p>0.05). Of all the artificial saliva-subgroups, only the difference between 'D/Sense Crystal' and 'Bifluorid 12' was significantly different (p<0.05). In SEM analysis, morphological changes were detected on the dentin surface and within the tubules following desensitizer treatments and post-treatments. CONCLUSION All the desensitizers significantly reduced dentin permeability by changing the morphology of the dentin surface and/or dentinal tubules. Following post-treatments, there was some reduction in the efficacy of the desensitizers which was represented by the reduction in permeability values. SEM analysis revealed some physical changes in the dentin structure which can partly give an explanation to the reduced efficacy of tested desensitizers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of desensitizing agents on dentin permeability and dentin tubule occlusion.

PURPOSE The aim of this study was to evaluate: 1) the effect of five dentin desensitizing agents (DDAs) on permeability using hydraulic conductance, and 2) morphological tubule changes with scanning electron microscopy (SEM). MATERIALS AND METHODS The agents tested were Seal & Protect, Gluma Desensitizer, HurriSeal, D/Sense 2, and Super Seal. Thirty extracted human molars were sectioned into ...

متن کامل

In vitro dentin permeability after application of Gluma® desensitizer as aqueous solution or aqueous fumed silica dispersion

OBJECTIVES To assess and to compare the effects of Gluma® Desensitizer (GDL) with an experimental glutaraldehyde and HEMA containing fumed silica dispersion (GDG) on dentin permeability using a chemiluminous tracer penetration test. MATERIAL AND METHODS Twenty disc-shaped dentin specimens were dissected from extracted human third molars. The dentin specimens were mounted in a split chamber de...

متن کامل

Effect of Erosion/Abrasion Challenge on the Dentin Tubule Occlusion Using Different Desensitizing Agents.

The aim of the study was to evaluate dentinal tubule occlusion, measuring the dentin permeability (Lp) and using different desensitizing agents before and after abrasive/erosive challenge. Dentin discs from 42 healthy human third molars were obtained. Minimum Lp was measured after a smear layer simulation using #600 SiC paper and maximum Lp after an immersion in 0.5 M EDTA. The specimens were t...

متن کامل

A Comparative Evaluation of Three Commercially Available Dentin Desensitizers on the Shear Bond Strength

Background: The dentin desensitizers available for in-office application for prevention and/or treatment of post restorative dentinal hypersensitivity, act by blocking the open dentinal tubules. In doing so, they may influence the bond strength of the restorative resins. Thus, the aim of the study was to evaluate the effect of desensitizers on the shear bond strength of dentin adhesives and to ...

متن کامل

Evaluation of the effect of two different desensitizing agents on shear bond strength of universal adhesive resin (an invitro study )

Background and Aim: dentin desensitizers may affect dentin organic matrix properties or occlude dentinal tubules which may have adverse effects on the bonding performance of adhesive systems. The aim of this study was invitro evaluation of Gluma desensitizer and Tokuyama Shield Plus effects or shear bond strength of (BISCO) all-bond universal bonding  system. Materials and Methods: 30 caries f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2017