Randomized controlled trial of the A.P. Advance, McGrath, and Macintosh laryngoscopes in normal and difficult intubation scenarios: a manikin study.

نویسندگان

  • E Burdett
  • D J Ross-Anderson
  • J Makepeace
  • P A Bassett
  • S G Clarke
  • V Mitchell
چکیده

BACKGROUND Several videolaryngoscopes are available which may facilitate tracheal intubation in difficult airways. We compared the McGrath(®) Series 5 and the Venner™ A.P. Advance™ (APA) videolaryngoscopes with a Macintosh laryngoscope by studying the performance of experienced anaesthetists using manikins in normal and difficult airway scenarios. METHODS We recruited 48 anaesthetists into a randomized trial. Each performed tracheal intubation with each laryngoscope in one easy and one difficult laryngoscopy scenario. The primary endpoint was time to intubation. Other endpoints were time to best glottic visualization, grade of view, and number of glottic advances. RESULTS There were no dropouts. In the easy scenario, the time to intubation was greater using the McGrath [median time 40.7 s, inter-quartile range (IQR) 31.0, 57.4, P<0.001] than the other devices. In the difficult scenario, the time to intubation using the APA with Difficult Airway Blade (DAB) was less (median time 23.2 s, IQR 19.8, 29.0, P<0.001) than the other devices. Time to glottic visualization was reduced using the McGrath and the APA with DAB. Glottic advances were fewer using the APA with DAB. CONCLUSIONS Experienced anaesthetists required a longer time for intubation in a standard manikin using a McGrath compared with other laryngoscopes, but a shorter time for intubation in a difficult manikin using an APA with DAB, and with fewer glottic advances, compared with other laryngoscopes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A randomised crossover trial comparing the Airtraq(®) NT, McGrath(®) MAC and Macintosh laryngoscopes for nasotracheal intubation of simulated easy and difficult airways in a manikin.

OBJECTIVE Several devices can aid nasotracheal intubation when managing difficult airways. The McGrath MAC and Airtraq NT were compared with a Macintosh laryngoscope when studying the performance of anaesthetists with different levels of experience, in a manikin model of easy or difficult airway scenarios. METHODS Sixty-three anaesthetists were recruited into a randomised trial in which each ...

متن کامل

Comparing McGRATH® MAC, C-MAC®, and Macintosh Laryngoscopes Operated by Medical Students: A Randomized, Crossover, Manikin Study

We hypothesized that the McGRATH MAC would decrease the time of intubation compared to C-MAC for novices. Thirty-nine medical students who had used the Macintosh blade to intubate a manikin fewer than 3 times were recruited. The participants performed sequential intubations on the manikin in two simulated settings that included a normal airway and a difficult airway (tongue edema). The intubati...

متن کامل

Comparison of the Glidescope® and Pentax AWS® laryngoscopes to the Macintosh laryngoscope for use by Advanced Paramedics in easy and simulated difficult intubation

BACKGROUND Intubation of the trachea in the pre-hospital setting may be lifesaving in severely ill and injured patients. However, tracheal intubation is frequently difficult to perform in this challenging environment, is associated with a lower success rate, and failed tracheal intubation constitutes an important cause of morbidity. Novel indirect laryngoscopes, such as the Glidescope and the A...

متن کامل

Comparison of the Airtraq® and Truview® laryngoscopes to the Macintosh laryngoscope for use by Advanced Paramedics in easy and simulated difficult intubation in manikins

BACKGROUND Paramedics are frequently required to perform tracheal intubation, a potentially life-saving manoeuvre in severely ill patients, in the prehospital setting. However, direct laryngoscopy is often more difficult in this environment, and failed tracheal intubation constitutes an important cause of morbidity. Novel indirect laryngoscopes, such as the Airtraq and Truview laryngoscopes may...

متن کامل

Comparison of Direct and Indirect Laryngoscopes in Vomitus and Hematemesis Settings: A Randomized Simulation Trial

BACKGROUND Videolaryngoscopes may not be useful in the presence of hematemesis or vomitus. We compared the utility of the Macintosh laryngoscope (McL), which is a direct laryngoscope, with that of the Pentax-AWS Airwayscope (AWS) and McGRATH MAC (McGRATH), which are videolaryngoscopes, in simulated hematemesis and vomitus settings. METHODS Seventeen anesthesiologists with more than 1 year of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 107 6  شماره 

صفحات  -

تاریخ انتشار 2011