Registration of cone beam computed tomography data and intraoral surface scans – A prerequisite for guided implant surgery with CAD/CAM drilling guides

نویسندگان

  • Tabea Flügge
  • Wiebe Derksen
  • Jobine Te Poel
  • Bassam Hassan
  • Katja Nelson
  • Daniel Wismeijer
چکیده

OBJECTIVES Guided implant surgery (GIS) is performed with drilling guides that are produced on the virtual tooth model using CAD/CAM technology. The prerequisite for this workflow is the alignment of patients cone beam computed tomography CBCT and surface scan (registration). Dental restorations may cause deteriorating imaging artifacts in CBCT data, which in turn can have an impact on the registration process. The influence of the user and the preprocessing of data and of image artifacts on the registration accuracy were examined. MATERIAL AND METHODS CBCT data and intraoral surface scans of 36 patients were used for virtual implant planning in coDiagnostiX (Dentalwings, Montreal, Canada). CBCT data were reconstructed to a three-dimensional anatomical model with the default settings provided by the software and also manually by four different examiners. Subsequently, the CBCT and intraoral surface models were registered by each examiner with the help of anatomical landmarks. Patients' data were subdivided into four groups (A-D) according to the number of metallic restorations: A = 0-2 restorations, B = 3-5 restorations, C = 6-8 restorations and D > 8 restorations. After registration, the distances between CBCT and dental surface models were measured. Linear regression models were used to assess the influence of the segmentation, the examiner and to the number of restorations (P < 0.05). RESULTS The deviations between surface scan and CBCT models accounted to 0.54 mm (mean). The mean deviations were 0.69 mm (max. 24.8 mm) and 0.4 mm (max. 9.1 mm) for default and manual segmentation, respectively. Mean deviations of 0.36 mm (Group A), 0.43 mm (Group B), 0.67 mm (Group C) and 1.01 mm (Group D) were recorded. The segmentation (P = 0.000), the user (P = 0.0052) and the number of restorations (P = 0.0337) had a significant influence on the registration accuracy. CONCLUSIONS The deviation between CBCT and surface scan model resulting from inaccurate registration is transferred to the surgical field and results in a deviation between the planned and actual implant position. The registration accuracy in commercial virtual implant planning software is significantly influenced by the preprocessing of imported data, by the user and by the number of restorations resulting in clinically non-acceptable deviations encoded in drilling guides.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of prevalence and pattern of maxillary sinus mucosal thickening in cone beam computed tomography of dental implant candidates in Shiraz, Iran

BACKGROUND AND AIM: This study aimed to assess maxillary sinus floor membrane thickness and ostium patency (OP) in patients undergoing cone beam computed tomography (CBCT) evaluation for implant placement in the posterior maxilla. Mucosal thickening (MT) could be cause of post-operative complications in implant procedures; awareness of this incidence could help proper detection and further succ...

متن کامل

Accuracy of computer-guided implant surgery by a CAD/CAM and laser scanning technique.

OBJECTIVES To explore the method of manufacturing an implant surgery template with a computer-aided design/computer-aided manufacturing (CAD/CAM) technique and evaluate its precision in clinical cases. METHODS Patients referred to the 2nd Dental Center of Peking University who were partially edentulous, were enrolled and scanned with cone beam computed tomography (CBCT). Diagnostic casts were...

متن کامل

Accuracy of surgical guides made from conventional and a combination of digital scanning and rapid prototyping techniques.

STATEMENT OF PROBLEM Surgical guides aid in accurately placing dental implants to achieve a predictable restorative outcome. Which surgical guide fabrication technique results in the most accurately fitting surgical guide is unknown. PURPOSE The purpose of this investigation was to determine the internal fit of dental implant surgical guides on dentate and edentulous ridges by using implant s...

متن کامل

Guided implant surgery with placement of a presurgical CAD/CAM patient-specific abutment and provisional in the esthetic zone.

Parallel use of implant treatment planning software and cone-beam computed tomography (CBCT) can, using certain criteria, consolidate steps and streamline tooth replacement strategies. The authors describe such a case in the esthetic zone whereby flapless extraction and immediate implant placement using CT-guided surgery were performed simultaneously, with placement of a computer-aided design/c...

متن کامل

Comparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects

Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects.&nbsp; Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 28  شماره 

صفحات  -

تاریخ انتشار 2017