Overestimation of the 25(OH)D serum concentration with the automated IDS EIA kit.

نویسندگان

  • Etienne Cavalier
  • Véronique Huberty
  • Catherine Cormier
  • Jean-Claude Souberbielle
چکیده

We have recently observed an increasing number of patients presenting very high serum levels of 25-hydroxyvitamin D [25(OH)D] (> 150 ng/mL), which, in all cases, had been measured with the IDS EIA kit adapted on different "open" automated platforms. We performed a comparison between the IDS EIA kit adapted on two different "open"automated platforms and the DiaSorin RIA. We found a systematic bias (higher levels with the IDS EIA kit) for concentrations more than 50-60 ng/mL that was less obvious when the IDS EIA was used in its manual procedure. We thus suggest to use the IDS EIA kit in its manual procedure rather than to adapt it on an automated platform, and to interpret cautiously a 25(OH)D greater than 100 ng/mL with this kit.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Method evaluation study of a new generation of vitamin D assays

INTRODUCTION Recently several diagnostic manufacturers have launched new 25-hydroxy-vitamin D (25[OH]D) assays, which are aligned to the National Institute of Standards and Technology (NIST) Standard Reference Materials (SRM) (NIST, Gaithersburg, Maryland). The aim of this study was to compare the performance of one liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, one enzyme li...

متن کامل

Comparison of commercially available (125)I-based RIA methods for the determination of circulating 25-hydroxyvitamin D.

BACKGROUND Measurement of circulating 25-hydroxyvitamin D [25(OH)D] is important in the management of metabolic bone disease. The aim of this study was to compare two widely used methods for the quantification of circulating 25(OH)D with attention to their abilities to measure 25-hydroxylated ergocalciferol (vitamin D(2)) [25(OH)D(2)] and cholecalciferol (vitamin D(3)) [25(OH)D(3)]. METHODS W...

متن کامل

What is the definition of \"vitamin D deficiency\" and who is considered \"vitamin D deficient\"? Urgent need for a national consensus

since early works on isolation and characterization of vitamin D by Elmer Verner McCollum and Edward Mellanby in 1900s, this molecule still seems mysterious (1-2). After several decades since discovery of the miraculous effect of cod liver oil in treatment of nutritional rickets, escalating number of reports provide a huge body of evidence for various effects of vitamin D ...

متن کامل

Evaluation of a 1,25-dihydroxyvitamin D enzyme immunoassay.

BACKGROUND Radioactive reagents are used in most assays for measurement of 1,25-dihydroxyvitamin D [1,25(OH)(2)D]. We evaluated a 1,25(OH)(2)D enzyme immunoassay (EIA) from IDS Ltd. that uses solid-phase immunoextraction and colorimetric detection and compared results to those of the thymus radioreceptor assay (RRA) for 1,25(OH)(2)D. METHODS We collected serum samples (n = 145) representing a...

متن کامل

25(OH) vitamin D serum values and rheumatoid arthritis disease activity (DAS28ESR)

Background: The role of vitamin D in the pathogenesis of rheumatoid arthritis is under investigation. This study was designed to evaluate the correlation between serum values of 25(OH) vitamin D [25(OH)D] and disease activity in rheumatoid arthritis (RA) patients according to Disease Activity Score 28 joints and ESR (DAS28ESR). Methods: Ninety-nine patients according to ACR classification crit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research

دوره 26 2  شماره 

صفحات  -

تاریخ انتشار 2011