Reconstruction of bone loading conditions from in vivo strain measurements.
نویسندگان
چکیده
A method is described whereby bone loading conditions can be reconstructed from in vivo strain measurements. The method uses ex vivo calibration measurements to find the relationship between the strain data and the loads applied to the bone. Using singular value decomposition, a transformation matrix is determined which provides the best linear relationship available between the measured strain data and the measured loading components in the calibration measurements. The transformation matrix can then be used to calculate the loads which correspond best with any given strain data set made with that specific bone and strain gages. In this manner, the applied loads of earlier performed in vivo strain measurements can be reconstructed. The method was tested for the reconstruction of the loads on a tibia of a goat. After determining the transformation matrix from a set of calibration measurements, the transformation matrix was used to reconstruct all loading components (three forces and three moments) of a set of test measurements whereby the applied loads were measured. It was found that the axial force and the torsional moment on the bone could be reproduced very accurately, showing a root mean square error (RMSE) of only 2% of the maximal load in the test. The reconstruction of the bending moments was slightly worse, showing a RMSE of 5-8% of the maximal moments. The reconstruction of the transverse force components proved less accurate and a RMSE up to 24% of the maximum was found. Accuracy can be improved by using weight factors for the loading conditions and a more accurate measurement of the location of the loads during the calibration measurements.
منابع مشابه
Reconstruction of Bone Loading Conditions from in Vw0 Strain Measurements
A method is described whereby bone loading conditions can be reconstructed from in oiuo strain measurements. The method uses ex uivo calibration measurements to find the relationship between the strain data and the loads applied to the bone. Using singular value decomposition, a transformation matrix is determined which provides the best linear relationship available between the measured strain...
متن کاملتعیین توزیع تنش و کرنش استخوان اطراف ایمپلنت در طرح All-on-4 به روش آنالیز اجزای محدود
Background and Aims: The All-on-4 design with its significant advantages is an appropriate model in reconstruction of edentulous mandible. Evaluation of stress and strain distribution in this model is necessary for better judgment. The purpose of this FEA study was to measure stress and strain distribution on peri-implant bone in All-on-4 design in edentulous mandible. Materials and Methods: Th...
متن کاملIn vivo measurements of the loading conditions on the tibia of the goat.
In vivo strain measurements at 8 locations on the tibia of the goat were performed. Successive in vitro calibrations were used to determine the assumed linear relationship between the measured strain signals and the external loads (3 forces and 3 moments) at the tibia. For the reconstruction of the in vivo external loads from the strain data, a transformation matrix was created from the calibra...
متن کاملDiagnosis of Delaminated Composites Using Post-processed Strain Measurements under Impact Loading
Potentially having a destructive influence on the mechanical properties of composite laminates, the invisible phenomenon of delamination frequently occurs under impact loading. In the present study, simulating the performance of long-gauge fiber Bragg grating sensors, impact-induced average strains within laminated composites are utilized to develop a delamination identification technique. Firs...
متن کاملEx vivo determination of bone tissue strains for an in vivo mouse tibial loading model
Previous studies introduced the digital image correlation (DIC) as a viable technique for measuring bone strain during loading. In this study, we investigated the sensitivity of a DIC system in determining surface strains in a mouse tibia while loaded in compression through the knee joint. Specifically, we examined the effect of speckle distribution, facet size and overlap, initial vertical ali...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biomechanics
دوره 28 6 شماره
صفحات -
تاریخ انتشار 1995