The lower bound on the timing resolution of scintillation detectors.
نویسندگان
چکیده
The timing performance of scintillation detectors is ultimately limited by photon counting statistics. In fact, photon counting statistics form a dominant contribution to the overall timing resolution of many state-of-the-art detectors. A common approach to investigate this contribution is to calculate the variance in the registration times of individual scintillation photons within the photosensor. However, in general the single-photon variance is not equal to the intrinsic limit on the timing resolution, since in principle one can make use of the timing information carried by all photons detected. In this work, the Cramér-Rao lower bound on the timing resolution of a scintillation detector, based on the information contained in the full set of registered photons, is calculated. The results appear to be in good agreement with trends observed in the literature. Furthermore, it is shown that the timestamp obtained from any single scintillation photon never yields the optimum timing resolution for realistic scintillation detectors. Yet, it appears that the intrinsic timing resolution limit can be approached closely by making use of the timestamps from a relatively small number of photons emitted during the initial part of the scintillation pulse.
منابع مشابه
Growth of CsI(Tl) crystals doped with Ca and Tm and investigation of its scintillation characteristics
In this work, the growth of CsI(Tl) crystals as gamma detector was performed using vertical Bridgman method with Ca and Tm co-dopants. For evaluation of the growth crystals, X-Ray Diffraction (XRD), photoluminescence and thermoluminescence spectra as well as recorded gamma spectra were employed. In addition, the scintillation properties including energy resolution, scintillation decay time, abs...
متن کاملLower bounds on scintillation detector timing performance
Fundamental method-independent linuts on the timing performance of scintillation detectors are useful for identifying regimes in which either present timing methods are nearly optimal or where a considerable performance gain might be realized using better pulse processing techniques . Several types of lower bounds on mean-squared timing error (MSE) performance have been developed and applied to...
متن کاملInvestigating the capability of plastic scintillation detectors in design of a muon radiography system by Geant4 code
Imaging and identifying materials with high atomic numbers and densities, especially radioactive materials, is one of the issues that have been especially considered in recent years. Due to some limitations in conventional and old imaging techniques, finding an alternative method is very important. The cosmic muons with an infinite source are one of the sources that have been recently studied f...
متن کاملبررسی رفتار آشکارساز سوسوزن آرایه رصدخانه البرز با روش شبیهسازی مونت کارلو در بستر نرمافزاری جیانت۴
For their appropriate temporal resolution, scintillator detectors are used in the Alborz observatory. In this work, the behavior of the scintillation detectors for the passage of electrons with different energies and directions were studied using the simulation code GEANT4. Pulse shapes of scintillation light, and such characteristics as the total number of photons, the rise time and the fallin...
متن کاملNew approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras
Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physics in medicine and biology
دوره 57 7 شماره
صفحات -
تاریخ انتشار 2012