Influence of fMRI data sampling on the temporal characterization of the hemodynamic response.

نویسندگان

  • Bixente Dilharreguy
  • Richard A Jones
  • Chrit T W Moonen
چکیده

Experimental and modeling studies were used to estimate the effect of different sampling rates (repetition times, TR) and different sampling positions on the estimates of the temporal properties of the hemodynamic response function (HRF) derived from fMRI studies. Data were acquired at a TR of 250 ms and then subjected to various degrees of undersampling. Using a gaussian fitting function it is demonstrated that the accuracy of HRF peak time determination decreases with lower sampling rate (higher TR). The decrease in accuracy amounts to about 50 ms per second of TR increase. In addition, temporal shifts of the HRF peak time are found when reducing the influence of the more variable descending part of HRF curve by using a temporal cut-off after HRF peak time. The shift scales with TR, amounts up to 100 ms for a TR of 1500 ms and a cut-off of 3-4 s and depends on the sampling position. The use of the full HRF function does not lead to a shift but increases the influence of potential confounding factors as large veins and poststimulus undershoot. Since both accuracy and potential shifts of HRF peak determination scale with TR, it is important that temporal fMRI studies are carried out with high sampling rates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Hemodynamic Response Function in Vision and Motor Brain Regions for the Young and Elderly Adults

Introduction: Prior studies comparing Hemodynamic Response Function (HRF) in the young and elderly adults based on fMRI data have reported inconsistent findings for brain vision and motor regions in healthy aging. It is shown that the averaging method employed in all previous works has caused this inconsistency. The averaging is so sensitive to outliers and noise. However, fMRI data are o...

متن کامل

Improving the Performance of ICA Algorithm for fMRI Simulated Data Analysis Using Temporal and Spatial Filters in the Preprocessing Phase

Introduction: The accuracy of analyzing Functional MRI (fMRI) data is usually decreases in the presence of noise and artifact sources. A common solution in for analyzing fMRI data having high noise is to use suitable preprocessing methods with the aim of data denoising. Some effects of preprocessing methods on the parametric methods such as general linear model (GLM) have previously been evalua...

متن کامل

An fMRI study of human visual cortex in response to spatiotemporal properties of visual stimuli

  ABSTRACT  Background: The brain response to temporal frequencies (TF) has been already reported, but with no study reported for different TF with respect to various spatial frequencies (SF).  Materials and Methods: fMRI was performed by 1.5T GE-system in 14 volunteers during checkerboard, with TFs of 4, 6, 8 and 10Hz in low and high SFs of 0.5 and 8cpd.  Results: Average percentage BOLD signa...

متن کامل

Pattern classification precedes region-average hemodynamic response in early visual cortex

How quickly can information about the neural response to a visual stimulus be detected in the hemodynamic response measured using fMRI? Multi-voxel pattern analysis (MVPA) uses pattern classification to detect subtle stimulus-specific information from patterns of responses among voxels, including information that cannot be detected in the average response across a given brain region. Here we us...

متن کامل

Brain Activity Map Extraction of Neuromyelitis Optica Patients Using Resting-State fMRI Data Based on Amplitude of Low Frequency Fluctuations and Regional Homogeneity Analysis

Introduction: Neuromyelitis Optica (NMO) is a rare inflammatory disease of the central nervous system which generally affecting the spinal cord and optic nerve. Damage to the optic nerve can result in the patient's dim vision or even blindness, while the spinal cord damage may lead to sensory and motor paralysis and the weakness of the lower limbs in the patient. Magnetic Reson...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • NeuroImage

دوره 19 4  شماره 

صفحات  -

تاریخ انتشار 2003