Dynamic Distortion Correction for Endoscopy Systems with Exchangeable Optics
نویسندگان
چکیده
Endoscopic images are strongly affected by lens distortion caused by the use of wide angle lenses. In case of endoscopy systems with exchangeable optics, e.g. in bladder endoscopy or sinus endoscopy, the camera sensor and the optics do not form a rigid system but they can be shifted and rotated with respect to each other during an examination. This flexibility has a major impact on the location of the distortion centre as it is moved along with the optics. In this paper, we describe an algorithm for the dynamic correction of lens distortion in cystoscopy which is based on a one time calibration. For the compensation, we combine a conventional static method for distortion correction with an algorithm to detect the position and the orientation of the elliptic field of view. This enables us to estimate the position of the distortion centre according to the relative movement of camera and optics. Therewith, a distortion correction for arbitrary rotation angles and shifts becomes possible without performing static calibrations for every possible combination of shifts and angles beforehand.
منابع مشابه
Evaluation of different distortion correction methods and interpolation techniques for an automated classification of celiac disease☆
Due to the optics used in endoscopes, a typical degradation observed in endoscopic images are barrel-type distortions. In this work we investigate the impact of methods used to correct such distortions in images on the classification accuracy in the context of automated celiac disease classification. For this purpose we compare various different distortion correction methods and apply them to e...
متن کاملRobust Wave-front Correction in a Small-Scale Adaptive Optics System Using a Membrane Deformable Mirror
A small-scale laboratory adaptive optics system using a Shack-Hartmann wave-front sensor (WFS) and a membrane deformable mirror (DM) has been built for robust image acquisition. In this study, an adaptive limited control technique is devised to maintain the long-term correction stability of the adaptive optics system. To prevent the waste of dynamic correction range for small residual wave-fron...
متن کاملNon-contact Adaptive Optic Actuator System for Wavefront Distortion Correction
INTRODUCTION Adaptive optic systems are used in ground-based telescope systems for correcting atmospheric wavefront distortions. Current adaptive optic systems are also used in microscopes, high power lasers and tomography to correct for tissue density and heat effects. Requirements for optical systems are more demanding in terms of resolution and manufacturing. While conventional adaptive opti...
متن کاملCorrection on the distortion of Scheimpflug imaging for dynamic central corneal thickness.
The measurement of central corneal thickness (CCT) is important in ophthalmology. Most studies concerned the value at normal status, while rare ones focused on its dynamic changing. The commercial Corvis ST is the only commercial device currently available to visualize the two-dimensional image of dynamic corneal profiles during an air puff indentation. However, the directly observed CCT involv...
متن کاملNew approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras
Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...