A high throughput dried DMSO LogD lipophilicity measurement based on 96-well shake-flask and atmospheric pressure photoionization mass spectrometry detection.
نویسندگان
چکیده
A rapid throughput octanol-water lipophilicity measurement based on 96-well shake-flask and LC/UV/APPI/MS is described. The method utilizes central liquid storage where compounds are stored as 10 mM solutions in dimethyl sulfoxide (DMSO). The DMSO is subsequently removed to generate solid like material used for LogD measurement. The removal of DMSO minimizes the concern for potential DMSO cosolvent effect on the measured value. Sample preparation is automated using a liquid handling workstation with 96-well pipetter. Both octanol and buffer phases are quantified using state of the art ultra-high pressure HPLC coupled with a superficially diffused core reversed-phase column and an atmospheric pressure photo ionization mass spectrometer. The throughput of the method is two days for a batch of 96 compounds. The method has been validated using 72 literature compounds with diverse ionization and LogD values ranging from -2 to +6. The observed coefficient of determination r(2) is 0.9973.
منابع مشابه
Electron capture atmospheric pressure photoionization mass spectrometry: analysis of fullerenes, perfluorinated compounds, and pentafluorobenzyl derivatives.
An electron capture (EC) ionization mechanism has been found to be highly efficient in negative-ion atmospheric pressure photoionization (APPI) for the analysis of compounds with positive electron affinity (EA). Using negative-ion APPI, we first report the sensitive detection of natural electrophores with limited polarity, such as fullerenes and perfluorinated compounds, by mass spectrometry (M...
متن کاملRelative hydrophobicity and lipophilicity of drugs measured by aqueous two-phase partitioning, octanol-buffer partitioning and HPLC. A simple model for predicting blood-brain distribution.
Relative hydrophobicity and lipophilicity of 63 compounds with known permeability through the blood-brain barrier (BBB) was examined by partitioning in aqueous dextran-poly(ethylene glycol) two-phase system and octanol-buffer system, and by gradient RP-HPLC at pH 7.4. Combination of the relative hydrophobicity estimates, N(CH(2)) obtained by aqueous two-phase partitioning and the lipophilicity ...
متن کاملChemical ionization mass spectrometry technique for detection of dimethylsulfoxide and ammonia
cluster ions is a function of cluster size with reactivity decreasing as cluster size increases. Ethanol cluster ion distributions that formed at atmospheric pressure from 24 ppbv, 900 ppmv, and 1% ethanol/N2 gas mixtures were studied. Small (C2H5OH)nH + clusters, those formed using the 24 ppbv ethanol/N2 mixture, react at or near the collisional rate with DMSO, NH3, acetone, and methyl vinyl k...
متن کاملAtmospheric pressure photoionization mass spectrometry.
Atmospheric pressure photoionization (APPI) is the last arrival in the family of atmospheric pressure ionization (API) methods to couple mass spectrometry (MS) to liquid-phase separation techniques. The basic idea was to further extend the fields of application of liquid chromatography (LC)-MS to those molecules that are not, or are poorly amenable, to electrospray (ESI) or APCI. The present re...
متن کاملAnalysis of Polymer Additives and Impurities by Liquid Chromatography/Mass Spectrometry and Capillary Electrophoresis/Mass Spectrometry
The analysis of polymeric materials can be quite challenging because such samples are often of complex nature due to the presence of various groups of additives, compounding ingredients, and fillers. Of special importance are stabilizers that protect the material from degradation by thermal stress during manufacture or from environmental impact during use. Apart from intact stabilizers, the deg...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography. A
دوره 1217 12 شماره
صفحات -
تاریخ انتشار 2010