Bacterial contamination of the hands of hospital staff during routine patient care.

نویسندگان

  • D Pittet
  • S Dharan
  • S Touveneau
  • V Sauvan
  • T V Perneger
چکیده

BACKGROUND Cross-transmission of microorganisms by the hands of health care workers is considered the main route of spread of nosocomial infections. OBJECTIVE To study the process of bacterial contamination of health care workers' hands during routine patient care in a large teaching hospital. METHODS Structured observations of 417 episodes of care were conducted by trained external observers (S.T. and V.S.). Each observation period started after a hand-cleansing procedure and ended when the health care worker proceeded to clean his or her hands or at the end of a coherent episode of care. At the end of each period of observation, an imprint of the 5 fingertips of the dominant hand was taken and bacterial colony counts were quantified. Regression methods were used to model the intensity of bacterial contamination as a function of method of hand cleansing, use of gloves during patient care, duration and type of care, and hospital ward. RESULTS Bacterial contamination increased linearly with time on ungloved hands during patient care (average, 16 colony-forming units [CFUs] per minute; 95% confidence interval, 11-21 CFUs per minute). Patient care activities independently (P<.05 for all) associated with higher contamination levels were direct patient contact, respiratory care, handling of body fluid secretions, and rupture in the sequence of patient care. Contamination levels varied with hospital location; the medical rehabilitation ward had higher levels (49 CFUs; P=.03) than did other wards. Finally, simple hand washing before patient care, without hand antisepsis, was also associated with higher colony counts (52 CFUs; P=.03). CONCLUSIONS The duration and type of patient care affect hand contamination. Furthermore, because hand antisepsis was superior to hand washing, intervention trials should explore the role of systematic hand antisepsis as a cornerstone of infection control to reduce cross-transmission in hospitals.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microbial Contamination of Staff’s Hand while Going out of Hospital

Abstract Background and Objective: Cross-transmission of microorganisms by the hands of health care workers is considered as a main transmission route of nosocomial infections. The aim of this study was to investigate the microbial contamination of health-care worker’s hands while going out of hospital. Material and Methods: Wearing the sterile glove with liquid culture, we obtained 100 Sam...

متن کامل

Comments on "Study of Bacterial Contamination of Mobile Phones and Stethoscopes in Neonatal Intensive Care Unit"

This letter is regarding the article by Daoudi et al. entitled "Study of bacterial contamination of mobile phones and stethoscopes in Neonatal Intensive Care Unit" published in International Journal of Pediatrics DOI: 10.22038/IJP.2017.25504.2170 (1). The authors have evaluated the microbial contamination of mobile phones and stethoscopes used by medical and paramedical staff. They reported tha...

متن کامل

Evaluation of bacterial and fungal contamination in the health care workers' hands and rings in the intensive care unit.

INTRODUCTION Nosocomial infections remain a major challenge to the health care system and result in significant mortality, morbidity, and economic burden. Intensive care unit (ICU) patients are at great risk of acquiring nosocomial infections. The objective of this study was to determine the contamination rate (bacterial and fungal) of the health care workers' (HCWs') hands and ring in ICU. M...

متن کامل

Bacterial Agents Isolated from Wards’ Environment and Staff’s Hands in Yahyanejad Hospital, Babol

Abstract Background and Objective: Nowadays, nosocomial infection is one of the greatest problems in hospitals. Normal flora of staff’s hands and the bacterial agents on the surface of medical equipment can become progressively colonized with potential pathogens during patient care. This study was carried out to determine the bacterial agents existed on staff’s hands and in the wards of ho...

متن کامل

The frequency of bacterial contamination and diversity of drug resistance patterns in devices and staff of endoscopy and colonoscopy units

Background: This study aimed at analyzing microbial contamination in medical equipment, environment, and staff of a gastroenterology unit. &nbsp;&nbsp; Methods: Samples of gastrointestinal imaging devices, the environment, and staff were collected using standard swab-rinse technique and biochemical or molecular characteristics of the isolates, their susceptibility to antibiotics, and similarit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Archives of internal medicine

دوره 159 8  شماره 

صفحات  -

تاریخ انتشار 1999