Reliability and validity of the closed kinetic chain upper extremity stability test
نویسندگان
چکیده
[Purpose] The purpose of this study was to examine the reliability and validity of the Closed Kinetic Chain Upper Extremity Stability (CKCUES) test. [Subjects and Methods] A sample of 40 subjects (20 males, 20 females) with and without pain in the upper limbs was recruited. The subjects were tested twice, three days apart to assess the reliability of the CKCUES test. The CKCUES test was performed four times, and the average was calculated using the data of the last 3 tests. In order to test the validity of the CKCUES test, peak torque of internal/external shoulder rotation was measured using an isokinetic dynamometer, and maximum grip strength was measured using a hand dynamometer, and their Pearson correlation coefficients with the average values of the CKCUES test were calculated. [Results] The reliability of the CKCUES test was very high (ICC=0.97). The correlations between the CKCUES test and maximum grip strength (r=0.78-0.79), and the peak torque of internal/external shoulder rotation (r=0.87-0.94) were high indicating its validity. [Conclusion] The reliability and validity of the CKCUES test were high. The CKCUES test is expected to be used for clinical tests on upper limb stability at low price.
منابع مشابه
Development of Screening Test Battery for Volleyball Players: A Mixed Method Study
Purpose: Design and development of functional movement screening in athletes are one of the important measures taken for reducing the injury in professional sports. Today, functional movement screening aimed at identifying athletes susceptible to injury is designed and implemented based on fundamental functional patterns and the performance of that particular sport. Currently, there are no stan...
متن کاملTest-retest Reliability of the Closed Kinetic Chain Upper Extremity Stability Test (ckcuest) in Adolescents: Reliability of Ckcuest in Adolescents.
BACKGROUND The Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST) has been proposed as an option to assess upper limb function and stability; however, there are few studies that support the use of this test in adolescents. PURPOSE The purpose of the present study was to investigate the intersession reliability and agreement of three CKCUEST scores in adolescents and establish clini...
متن کاملبررسی ثبات عملکردی اندام فوقانی هندبالیستهای دارای نقص چرخش داخلی شانه
Objective: Glenohumeral Internal Rotation Deficit is one of the important risk factors in throwing athletes that can cause adverse effects on glenohumeral joint biomechanics during throwing activity and overhead activity. Methods: In this descriptive study, 30 male student Hanballers (age=18 to 25 years) were categorized into healthy (n=15) and Glenohumeral Internal Rotation Deficit (n=15) gro...
متن کاملClosed Kinetic Chain Upper Extremity Stability test (CKCUES test): a reliability study in persons with and without shoulder impingement syndrome
BACKGROUND The Close Kinetic Chain Upper Extremity Stability Test (CKCUES test) is a low cost shoulder functional test that could be considered as a complementary and objective clinical outcome for shoulder performance evaluation. However, its reliability was tested only in recreational athletes' males and there are no studies comparing scores between sedentary and active samples. The purpose w...
متن کاملFunctional Movement Screening Tests for the Prediction of Injuries in Volleyball: A Qualitative Study
Background. There is little evidence to support the comprehensiveness of FMS in sports populations to predict injuries. Ignoring rapid decelerations and high eccentric forces which may be characteristics of high risk for injury are evident in these tests. With this in mind, it seems logical to use tests to assess the performance of athletes so as to evaluate speed components as well as to ident...
متن کامل