Four-year outcomes with third-generation centrifugal left ventricular assist devices in an era of restricted transplantation

نویسندگان

  • Faruk Özalp
  • Sai Bhagra
  • Catriona Bhagra
  • Tanveer Butt
  • Bandigowdanapalya Ramesh
  • Nicola Robinson-Smith
  • Neil Wrightson
  • Gareth Parry
  • Massimo Griselli
  • Asif Hasan
  • Stephan Schueler
  • Guy A. MacGowan
چکیده

OBJECTIVES Third-generation ventricular assist devices (VADs) are associated with improved outcomes, though in recent clinical trials bridge-to-transplant (BTT) rates are ∼30% at 6 months, so that transplantation can be used as a 'bail out' for serious complications. In the UK, there was a significant reduction in heart transplantation rates over the last decade, so that transplantation from VADs is much less frequent. The objective of this study was to determine outcomes and their predictors in this situation of low BTT rates, and as patients were exposed to long-term support, the incidence and outcomes of VAD thrombosis. METHODS We analysed outcomes for 102 consecutive patients between 2009 and 2013 (mean age 47 ± 13; VentrAssist n = 6 and HeartWare n = 96). The median duration of support was 462 ± 426 days. RESULTS Survival rates on the device were 75 and 66% at 1 and 2 years, respectively. Older age and more acute INTERMACS groups were significantly related to reduced survival within the first 90 days (P = 0.030 and 0.010, respectively). Poor preoperative right ventricular (RV) function had a negative effect on survival after 1 year (P = 0.009), though not earlier. VAD thrombosis (n = 24 HeartWare and n = 1 VentrAssist) occurred at 0.18 events per patient-year for HeartWare and 0.07 for VentrAssist devices at a median time of onset at 404 ± 281 days. There was no significant effect of VAD thrombosis on survival. Only 14 of 102 patients were transplanted at a median of 334 ± 347 days, and only 3 were transplanted within the first 6 months. CONCLUSIONS Third-generation left ventricular assist device implants with a low rate of transplantation have similar survival to destination therapy, and are susceptible to long-term complications of VAD thrombosis and right heart failure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)

Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...

متن کامل

Three-year outcomes with left ventricular assist devices in country with restricted heart transplantation

Background/Introduction As a consequence of limited donor availability, there has been a growing interest for alternative strategies, such as left ventricular assist devices (LVAD) as either a bridge to transplantation (BTT) or as destination therapy (DT) for the treatment of the advanced heart failure. The heart transplant program in Kazakhstan is in a nascent stage and therefore patients that...

متن کامل

Looking Inside the Third Generation Left Ventricular Assist Device Using Color Doppler Transesophageal Echocardiography

HeartWare is a third-generation continuous flow left ventricular assist device (LVAD) and generates centrifugal pattern of blood flow. In the perioperative setting, interrogating the HeartWare devices is very difficult due to the interference of the Doppler by the impeller frequency and generation of the waterfall artifact. We present a case where using color Doppler a view "inside" the impelle...

متن کامل

DuraHeart magnetically levitated centrifugal left ventricular assist system for advanced heart failure patients.

The implantable left ventricular assist system (LVAS) using pulsatile pump technology has become an established therapeutic option for advanced heart failure patients. However, there have been technological limitations in some older designs, including a high incidence of infection and mechanical failures associated with moving parts, and the large size of both implantable pump and percutaneous ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 46  شماره 

صفحات  -

تاریخ انتشار 2014