Complications of titanium and stainless steel elastic nail fixation of pediatric femoral fractures.

نویسندگان

  • Divesh Gulati
  • Aditya Aggarwal
  • Arun P Singh
چکیده

BACKGROUND In vitro mechanical studies have demonstrated equal or superior fixation of pediatric femoral fractures with use of titanium elastic nails as compared with stainless steel elastic nails, and the biomechanical properties of titanium are often considered to be superior to those of stainless steel for intramedullary fracture fixation. We are not aware of any clinical studies in the literature that have directly compared stainless steel and titanium elastic nails for the fixation of pediatric femoral fractures. The purpose of the present study was to compare the complications associated with the use of similarly designed titanium and stainless steel elastic nails for the fixation of pediatric femoral fractures. METHODS A group of fifty-six children with femoral fractures that were treated with titanium elastic nails was compared with another group of forty-eight children with femoral fractures that were treated with stainless steel elastic nails. Both nail types were of similar design, and a similar retrograde insertion technique was used. The groups were compared with regard to complications as well as insertion and extraction time. Major complications were defined as malunion with sagittal angulation of >15 degrees and coronal angulation of >10 degrees, nail irritation requiring revision surgery, infection, delayed union, and rod breakage. Minor complications were defined as nail irritation or superficial infection not requiring surgery. RESULTS The malunion rate was nearly four times higher in association with the titanium nails (23.2%; thirteen of fifty-six) as compared with the stainless steel nails (6.3%; three of forty-eight) (p = 0.017, chi-square test; odds ratio = 4.535 [95% confidence interval, 1.208 to 17.029]). The rate of major complications was 35.7% (twenty of fifty-six) for titanium nails and 16.7% (eight of forty-eight) for stainless steel nails. The rates of minor complications were similar for the two groups, as were the insertion times and extraction times. The supplier price of one titanium nail ranges from $259 to $328, depending on size, whereas the price of one stainless steel nail would be $78 in current United States dollars. CONCLUSIONS Our results indicate that the less expensive stainless steel elastic nails are clinically superior to titanium nails for pediatric femoral fixation primarily because of a much lower rate of malunion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of pediatric femoral shaft fractures by stainless steel and titanium elastic nail system: A randomized comparative trial

PURPOSE Literature suggests that the lower modulus of elasticity of titanium makes it ideal for use in children compared with stainless steel. Better fracture stability was observed in association with titanium nails on torsional and axial compression testing. However, stainless steel nails are stiffer than titanium counterparts, which may provide a rigid construct when fixing paediatric femora...

متن کامل

Randomized controlled trial comparing stabilization of fresh close femoral shaft fractures in children with titanium elastic nail system versus stainless steel elastic nail system.

In vitro mechanical studies have demonstrated equal or superior fixation of pediatric femoral fractures with use of titanium elastic nails (TENS) as compared with stainless steel elastic nails (SSEN). SSEN are less expensive as compared to TENS. However, there are only two studies in the English literature which have compared the results of TENS and SSEN in paediatric femoral shaft fracture. Th...

متن کامل

Biomechanical comparison of stainless steel and titanium nails for fixation of simulated femoral fractures.

Flexible intramedullary nails are commonly used to treat femoral fractures in children. This study evaluated the biomechanical differences between stainless steel and titanium nails when securing transverse and comminuted fractures in a synthetic femur model. Retrograde flexible stainless steel and titanium nails placed in a divergent "C" pattern were mechanically tested, and axial rotation and...

متن کامل

Elastic Stable Intramedullary Nailing of Femoral Shaft Fracture-Experience in 48 Children

Background: Femoral shaft fractures are an incapacitating pediatric injury accounting for 1.6% of all pediatric bonyinjuries. Management of these fractures is largely directed by age, fracture pattern, associated injuries, built of the childand socioeconomic status of the family. We retrospectively evaluated the use of elastic stable intramedullary nail (ESIN)in surgical management of femoral s...

متن کامل

Management of pediatric femoral shaft fractures with long intramedullary kirshner wires

I ntramedullary titanium elastic nails (TEN) have been used for treatment of the pediatric patients with femoral shaft fractures in the last 15 20 years. They are load bearing devices and are flexible to allow bending. Small incisions are required for introduction of these nails and they are easy to remove. High cost is a disadvantage. However in the developing countries, where cost and afforda...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. American volume

دوره 92 5  شماره 

صفحات  -

تاریخ انتشار 2008