Prophylactic replacement of Bjŏrk-Shiley convexo-concave heart valves: an easy-to-use tool to aid decision-making in individual patients.
نویسنده
چکیده
OBJECTIVE To develop an easy-to-use tool for decision-making on prophylactic replacement of Björk-Shiley convexo-concave heart valves. DESIGN Decision analysis comparing elective replacement with observation. SETTING Referral centres for patients with artificial heart valves. PATIENTS Quantitative estimates were obtained from a follow up study conducted in The Netherlands, including 2303 patients with a mean follow up of 6.6 years and from recently published studies. INTERVENTION Elective valve replacement with a new artificial heart valve. MAIN OUTCOME MEASURE Loss of life-expectancy. RESULTS A simple graph was constructed to present the loss of life-expectancy caused by strut fracture for combinations of basal life-expectancy (life-expectancy without strut fracture) and lethal fracture risk (strut fracture risk multiplied by lethality of fracture). This loss can be compared directly with the loss of life-expectancy caused by surgical mortality. This quantitative approach takes into account individual patient characteristics, such as age, gender, cardiac comorbidity, and position of the valve, but the final estimation of surgical mortality also requires clinical judgement. The calculations can be made easily by hand or with a simple computer application. CONCLUSIONS This decision support tool enables the direct estimation of the gain or loss of life-expectancy that is likely with replacement of a Björk-Shiley convexo-concave heart valve. It can be used to evaluate individual patients as well as groups of patients, and allows for easy incorporation of revisions of fracture risk estimates.
منابع مشابه
Age thresholds for prophylactic replacement of Björk-Shiley convexo-concave heart valves. A clinical and economic evaluation.
BACKGROUND Björk-Shiley convexo-concave heart valves have an increased risk of mechanical failure. One might consider prophylactic rereplacement as a preventive measure to avert the disastrous consequences of these failures. We investigated the effect that prophylactic rereplacement has on survival of individual patients and on the medical costs. METHODS AND RESULTS Quantitative estimates for...
متن کاملBjork-Shiley Convexo-concave Heart Valves A Clinical and Economic Evaluation
Background. Bjork-Shiley convexo-concave heart valves have an increased risk of mechanical failure. One might consider prophylactic rereplacement as a preventive measure to avert the disastrous consequences of these failures. We investigated the effect that prophylactic rereplacement has on survival of individual patients and on the medical costs. Methods and Results. Quantitative estimates for...
متن کاملDecision guidelines for prophylactic replacement of Björk-Shiley convexo-concave heart valves: impact on clinical practice.
BACKGROUND Because of risk of outlet strut fracture, prophylactic replacement should be considered for Björk-Shiley convexo-concave (BScc) valve recipients. We assessed the effects of epidemiological and decision-analytic guidelines on actual BScc valve replacement. METHODS AND RESULTS We performed a retrospective cohort study including all 2263 Dutch BScc patients with a mean follow-up of 11...
متن کاملThe Björk-Shiley convexo-concave heart valve experience from the perspective of the supervisory panel.
The 20-year activities of a medical supervisory panel appointed under the terms of a settlement agreement of the Bowling v. Pfizer class action suit involving the Björk-Shiley convexo-concave (BSCC) heart valve are detailed. Of approximately 86,000 valves implanted, catastrophic failure of the valve was reported in 663 patients from 1978 to 2012. In 1994, a 7-member medical panel consisting of ...
متن کاملBlack holes on MR images of the brain of patients with Björk-Shiley heart valves: additional observation in three cases.
We report the cases of three patients with Björk-Shiley convexo-concave heart valves with unusual black holes shown on cerebral MR images. For two patients, these findings were associated with fracture of the Björk-Shiley convexo-concave heart valve, and for the third, with worn surfaces on the heart valve. Susceptibility changes shown by MR imaging suggest the possibility that these black hole...