State-resolved reactive scattering by slice imaging: a new view of the Cl+C2H6 reaction.
نویسندگان
چکیده
We present state-resolved crossed beam scattering results for the reaction Cl+C2H6-->HCl+C2H5, obtained using direct current slice imaging. The HCl (v=0,J=2) image, recorded at a collision energy of 6.7+/-0.6 kcalmol, shows strongly coupled angular and translational energy distributions revealing features of the reaction not seen in previous studies. The overall distribution is mainly forward scattered with respect to the Cl beam, with a translational energy distribution peaking near the collision energy. However, there is a substantial backscattered contribution that is very different. It shows a sharp peak at 8.0 kcalmol, but extends to much lower energy, implying substantial internal excitation in the ethyl radical coproduct. These results provide new insight into the reaction, and they are considered in terms of alternative models of the dynamics. This work represents the first genuine crossed-beam study in which a product other than the methyl radical was detected with quantum state specificity, showing the promise of the approach generally for high resolution state-resolved reactive scattering.
منابع مشابه
Dc slice imaging, crossed beam reaction of chlorine radical with butane
DC SLICE IMAGING, CROSSED BEAM REACTION OF CHLORINE RADICALWITH BUTANEbyTAREK ABDUL GHANIDecember 2012Advisor: Dr. Arthur SuitsMajor: ChemistryDegree: Master of ScienceWe present an investigation of the reaction dynamics of Cl radicals withbutane in crossed beams, were studied at two collision energies: ~ 6.5 and 9kcal/mol. Product were ionized using a 15...
متن کاملEvaluation of MRI-based Polymer Gel Dosimetry for Measurement of CT Dose Index (CTDI) on 64 slices CT Scanners
Introduction: Computed tomography (CT) has numerous applications in clinical procedures but its main problem is its high radiation dose to the patients compared to other imaging modalities using x-ray. CT delivers approximately high doses to the nearby tissues due to the scattering effect, fan beam (beam divergence) and limited collimator efficiency. The radiation dose from multi-slice scanners...
متن کاملEffect of Slice Thickness on the Accuracy of Linear Measurements Made on Cone Beam Computed Tomography Images (InVitro
Objective: Cone beam computed tomography (CBCT) is applied for the imaging of the maxillofacial and dental structures, particularly for surgical treatments and dental implants. The aim of this study was to assess the effect of slice thickness on the accuracy of CBCT linear measurements. Methods: In this diagnostic accuracy study, forty-two titanium pins with the same dimensions were inserted...
متن کاملModeling Time Resolved Light Propagation Inside a Realistic Human Head Model
Background: Near infrared spectroscopy imaging is one of the new techniques used for investigating structural and functionality of different body tissues. This is done by injecting light into the medium and measuring the photon intensity at the surface of the tissue.Method: In this paper the different medical applications, various imaging and simulation techniques of NIRS imaging is described. ...
متن کاملScattering-phase theorem: anomalous diffraction by forward-peaked scattering media
The scattering-phase theorem states that the values of scattering and reduced scattering coefficients of the bulk random media are proportional to the variance of the phase and the variance of the phase gradient, respectively, of the phase map of light passing through one thin slice of the medium. We report a new derivation of the scattering phase theorem and provide the correct form of the rel...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of chemical physics
دوره 124 1 شماره
صفحات -
تاریخ انتشار 2006