Posterior augmentation of an anterior lumbar interbody fusion: minimally invasive fixation versus pedicle screws in vitro.

نویسندگان

  • Brian P Beaubien
  • Amir A Mehbod
  • Patricia M Kallemeier
  • William D Lew
  • Glenn R Buttermann
  • Ensor E Transfeldt
  • Kirkham B Wood
چکیده

STUDY DESIGN An in vitro biomechanical comparison of four posterior fixation techniques in the setting of an anterior lumbar interbody fusion (ALIF). OBJECTIVE To compare the initial stability, in terms of range of motion and neutral zone, provided by pedicle screws, facet screws, translaminar facet screws, and H-graft plus interspinous cables in the presence of an anteriorly placed femoral ring allograft. SUMMARY OF BACKGROUND DATA Pedicular fixation has been used to increase ALIF fusion rates but has also been linked with increased morbidity. Alternative posterior fixation options are available, but comprehensive biomechanical comparisons of these techniques do not exist. METHODS.: Twelve cadaveric lumbar motion segments were loaded to 5 Nm in unconstrained flexion-extension, lateral bending, and axial torsion. Specimens were tested intact, after ALIF, and after applying pedicle screws, translaminar screws, facet screws, and H-graft plus cables. The resulting neutral zones and ranges of motion were measured. RESULTS The mean (+/-SEM) range of motion for each construct in flexion-extension was as follows: intact: 6.39 degrees (+/-0.47 degrees); ALIF alone: 3.31 degrees (+/-0.22 degrees); (ALIF+) pedicle screws: 0.6 degrees (+/-0.06 degrees); facet screws: 0.75 degrees (+/-0.12 degrees); translaminar screws: 0.61 degrees (+/-0.09 degrees); and H-graft: 1.74 degrees (+/-0.26 degrees). Pedicle, translaminar facet, and facet screws significantly decreased range of motion and neutral zone compared to ALIF alone in flexion-extension, lateral bending, and axial torsion (all at P < 0.04, except translaminar screws in torsion neutral zone where P = 0.09). H-graft decreasedflexion-extension range of motion and neutral zone only (P < 0.01) and resulted in a significantly greater neutral zone than pedicle and facet screws in torsion and lateral bending neutral zones (P < 0.03). CONCLUSIONS In the ALIF setting, facet screw and translaminar screw techniques, which may be associated with less morbidity than pedicle screws clinically, provided initial posterior stabilization similar to pedicular fixation in this in vitro study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Role of Minimally Invasive Spine Surgery in Adults with Degenerative Lumbar Scoliosis: A Narrative Review

Background and Aim: Degenerative lumbar scoliosis is a spinal deformity resulting from advanced disc degeneration and facet arthropathy. Given the inconclusive available literature and lack of high-quality data supporting the role of minimally invasive surgical management of degenerative lumbar scoliosis, this review intends to highlight and compare the various viable minimally invasive surgica...

متن کامل

Finite Element Analysis of a New Pedicle Screw-Plate System for Minimally Invasive Transforaminal Lumbar Interbody Fusion

PURPOSE Minimally invasive transforaminal lumbar interbody fusion (MI-TLIF) is increasingly popular for the surgical treatment of degenerative lumbar disc diseases. The constructs intended for segmental stability are varied in MI-TLIF. We adopted finite element (FE) analysis to compare the stability after different construct fixations using interbody cage with posterior pedicle screw-rod or ped...

متن کامل

Biomechanical Evaluation of a Standalone Lumbar Interbody Cage with Integrated Screws

INTRODUCTION: Spinal fusion techniques including anterior lumbar interbody fusion (ALIF) have been used to alleviate chronic low back pain and segmental instability. Supplemental fixation using pedicle screws, translaminar screws, facet screws, anterior plates or spinous process plates is often used to increase the stability of the ALIF construct to enhance fusion and prevent subsidence and mig...

متن کامل

Hybrid technique for posterior lumbar interbody fusion: a combination of open decompression and percutaneous pedicle screw fixation.

The authors describe a hybrid technique that involves a combination of open decompression and posterior lumbar interbody fusion (PLIF) and percutaneously inserted pedicle screws. This technique allows performance of PLIF and decompression via a midline incision and approach without compromising operative time and visualization. Furthermore, compared to standard open decompression, this approach...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Spine

دوره 29 19  شماره 

صفحات  -

تاریخ انتشار 2004