Comparison of nasal pressure support ventilation with nasal intermittent positive pressure ventilation in patients with nocturnal hypoventilation.

نویسندگان

  • L J Restrick
  • N C Fox
  • G Braid
  • E M Ward
  • E A Paul
  • J A Wedzicha
چکیده

Nasal intermittent positive pressure ventilation (NIPPV) provides effective ventilatory support in patients with nocturnal hypoventilation. Nasal pressure support ventilation (NPSV), which only provides ventilation in response to patient triggering, may also be effective, simpler, and cheaper, but has not been evaluated. NIPPV and NPSV were compared in 12 patients with nocturnal hypoventilation, requiring domiciliary ventilatory support. The patients were studied on three consecutive nights, in random order: a control night without ventilation and a night on each mode of ventilatory support using the bilevel positive airway pressure (BiPAP) ventilator. Both NIPPV and NPSV significantly increased mean arterial oxygen saturation (SaO2) compared to the control night (NIPPV mean increase 4.1%; 95% confidence interval (CI) 2.2 to 6.1, NPSV 4.4%; CI 2.1 to 6.6) with no significant difference between the two modes. The percentage of the study night spent below 90% SaO2 was significantly reduced by both ventilator modes compared to the control night (median reduction on NIPPV 37%; CI -54 to -10, reduction on NPSV 31%; CI -53 to -9, with no significant difference between NPSV and NIPPV. NPSV was as effective as NIPPV in patients with nocturnal hypoventilation, which suggests that these patients are able to trigger the ventilator adequately. The lower cost of NPSV will make it accessible to more patients with chronic lung disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effectiveness of Nasal Intermittent Positive Pressure Ventilation versus Nasal Continuous Positive Airway Pressure in Preterm Infants after Less Invasive Surfactant Administration

Background Non-invasive ventilation is increased used in preterm infants. We aimed to compare the effectiveness of nasal intermittent positive pressure ventilation (nIPPV) versus nasal continuous positive airway pressure (nCPAP) in preterm infants with respiratory distress syndrome (RDS) after less invasive surfactant administration (LISA). Materials and Methods In this clinical trial, eighty ...

متن کامل

Early Nasal Intermittent Positive Pressure Ventilation (NIPPV) versus Nasal Continuous Positive Airway Pressure (NCPAP) for Respiratory Distress Syndrome (RDS) in Infants of 28-36 weeks gestational age: a Randomized Controlled Trial

Background: Early nasal continuous positive airway pressure (NCPAP) has emerged as a primary modality of respiratory support for preterm infants withrespiratory distress syndrome (RDS). However, 30%-40% of these newborns need subsequent mechanical ventilation. Nasal intermittent positive pressure ventilation (NIPPV) is a promising alternative to NCPAP, especially in po...

متن کامل

A Comparison between Nasal Intermittent Positive Pressure Ventilation and Nasal Continuous Positive Airway Pressure Ventilation in the Treatment of Neonatal Respiratory Distress Syndrome

Background: Nasal intermittent positive pressure ventilation (NIPPV) is a non-invasive ventilatory mode, which delivers mechanical ventilation via nasal tubes or prongs. The present study was conducted to compare the efficacy of NIPPV and nasal continuous positive airway pressure ventilation (NCPAP) in reducing the need for intubation in preterm infants with respiratory distress syndrome (RDS)....

متن کامل

Comparison of Nasal Non-invasive Ventilation Methods in Preterm Neonates with Respiratory Distress Syndrome

Background: Humidified heated high flow nasal cannula (HHHFNC), nasal continuous positive airway pressure (NCPAP), and nasal intermittent positive pressure ventilation (NIPPV) are three nasal non-invasive ventilation methods. The purpose of this study was to compare these three methods in decreasing intubation and mechanical ventilation rate in preterm neonates with respiratory distress syndrom...

متن کامل

A Comparative Study of Treatment Response of Respiratory Distress Syndrome in Preterm Infants: Early Nasal Intermittent Positive Pressure Ventilation versus Early Nasal Continuous Positive Airway Pressure

Background Infant respiratory distress syndrome (IRDS) is one of the main causes of serious complications and death in preterm infants. Both Nasal Continuous Positive Airway Pressure (NCPAP) and Nasal Intermittent Positive Pressure Ventilation (NIPPV) are known as the most common treatment strategies for IRDS. The present study intended to compare NCPAP and NIPPV in the treatment of preterm inf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 6 3  شماره 

صفحات  -

تاریخ انتشار 1993