Evaluation of accuracy of plain radiography in determining the Risser stage and identification of common sources of errors

نویسندگان

  • Jae Hyuk Yang
  • Amit Wasudeo Bhandarkar
  • Seung Woo Suh
  • Jae Young Hong
  • Jin Ho Hwang
  • Chang Hwa Ham
چکیده

BACKGROUND Risser's sign is an established radiological marker for predicting growth potential in adolescent idiopathic scoliosis, but the accuracy of Risser's staging has been debated. This research was designed to evaluate the accuracy of Risser's staging and to identify causes of errors in Risser's staging. MATERIALS AND METHODS Plain radiographs of 89 adolescent idiopathic scoliosis patients were evaluated for Risser's stage using both the Original and French methods. A three-dimensional computed tomography (3D-CT) was used to evaluate the accuracy of the plain radiographs. Inter- and intra-observer reliability of both methods was assessed on radiographs and 3D-CT images using weighted kappa statistics. The concordance rate for Risser's staging between plain radiographs and 3D-CT images were calculated. The various sources of staging differences between the two imaging methods were noted, grouped, and analyzed to identify common error patterns. RESULTS Intra- and inter-observer staging reliabilities on plain radiography were 0.91 and 0.94, respectively, using the Original method and 0.91 and 0.92, respectively, using the French method. Intra- and inter-observer reliabilities on 3D-CT were 0.98 and 0.99, respectively, using the Original method and 0.97 and 0.99, respectively, using the French method. Mean concordance rates between plain radiography and 3D-CT were 59.76% and 67.42% using the Original and French methods, respectively. Common sources of error leading to misinterpretation of Risser's staging were miscalculation of apophysis excursion, skip ossification, isolated non-linear ossification, micro-fusion, and pseudo-fusion. CONCLUSIONS Risser's staging by plain radiography is reliable but not accurate. Variations in the iliac apophysis ossification and misinterpretation of apophysis fusion are the main sources of error.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Ultrasonography in Diagnosis of Nasal Fracture and Compared it with Plain Radiography in Dogs

Objective- One of the important causes of nasal fracture is a trauma that can be diagnosed in clinical examinations and diagnostic imaging but it should be noted that radiography may show false fractures in the nose. This study evaluates the value of ultrasonography in the diagnosis of nasal fractures and compared it with plain radiography. Design- Retrospective study. Animals- 12 d...

متن کامل

ارزیابی سی‌‌تی‌‌اسکن اسپیرال در تشخیص بیماران مبتلا به درد شکم حاد غیرترومایی مراجعه‌کننده به بیمارستان سینا

Background: Acute abdominal pain is a common complaint in an emergency setting. An immediate and precise diagnosis is necessary for reducing morbidity and mortality. Several studies have reported that CT scan increases diagnostic accuracy for patients with acute abdominal pain. This study was designed to evaluate the sensitivity, specificity and accuracy of spiral CT scan compared to that of ab...

متن کامل

بررسی میزان موفقیت در جاگذاری 180 پیچ پدیکولار بکاررفته در شکستگی‌های ناپایدار ستون فقرات توراکولومبار با استفاده از رادیوگرافی ساده در حین عمل جراحی

  Background & Aims: Thuracolumbar Unstable Fractures (T, L.U.F) are common after spine truma. Posterior pedicular fixation is a technique that is use for fixation of these fractures. This study evaluates the accuracy of pedicular screw placement in T, LUF with the assistance of plain radiography in operation rooms.   Materials & Methods: This study is a case-control and analytical study. 35 pa...

متن کامل

Evaluation of the frequency of intra-oral radiographic errors in dental radiology department in Mashhad

Background and Aims: Dental diagnosis may be affected by the occurrence of the errors in the intra-oral radiographic images and the patients’ treatment plan can be problematic in these cases. The repetition of these radiographs increases the risks of radiation exposure for the patients in turn. The present study assessed the incidences of common periapical radiographic errors taken by dental st...

متن کامل

Evaluation of medication error reports sent to Food and Drug deputy from hospitals affiliated to Mazandaran University of Medical Sciences during 2015-2018

Background and purpose: Medical errors are one of the most common threats to patient safety. Medication errors have a number of consequences, including the increase in patient mortality, length of stay, and healthcare costs. Materials and Methods: This study was conducted by Food and Drug Deputy of Mazandaran University on medication errors reported received from covered hospitals during 201...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014