Hemostatic Effects of Microbubble-Enhanced Low-Intensity Ultrasound in a Liver Avulsion Injury Model

نویسندگان

  • Guiying Feng
  • Jianhua Liu
  • Xiaochen Zhao
  • Jinglu Wei
  • Wencai Ou
  • Shuyi Xiao
  • Zhiwen Hu
  • Hongqin Wei
  • Zheng Liu
چکیده

OBJECTIVES Microbubble-enhanced therapeutic ultrasound (MEUS) can block the blood flow in the organs. The aim of this study was to evaluate the hemostatic effect of microbubble-enhanced pulsed, low-intensity ultrasound in a New Zealand White rabbit model of avulsion trauma of the liver. The therapeutic ultrasound (TUS) transducer was operated with the frequency of 1.2 MHz and an acoustic pressure of 3.4 MPa. Microbubble-(MB) enhanced ultrasound (MEUS) (n = 6) was delivered to the distal part of the liver where the avulsion was created. Livers were treated by TUS only (n = 4) or MB only (n = 4) which served as controls. Bleeding rates were measured and contrast enhanced ultrasound (CEUS) was performed to assess the hemostatic effect, and liver hemoperfusion before and after treatment. Generally, bleeding rates decreased more than 10-fold after the treatment with MEUS compared with those of the control group (P<0.05). CEUS showed significant declines in perfusion. The peak intensity value and the area under the curve also decreased after insonation compared with those of the control group (P<0.05). Histological examination showed cloudy and swollen hepatocytes, dilated hepatic sinusoids, perisinusoidal spaces with erythrocyte accumulation in small blood vessels, obvious hemorrhage around portal areas and scattered necrosis in liver tissues within the insonation area of MEUS Group. In addition, necrosis was found in liver tissue 48 h after insonation. We conclude that MEUS might provide an effective hemostatic therapy for serious organ trauma such as liver avulsion injury.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of track microbubble flow signals on contrast-enhanced ultrasound with perflubutane following percutaneous liver biopsy.

OBJECTIVE It is important to detect post-liver biopsy hemorrhage early and confirm hemostasis in the clinical setting. Contrast-enhanced ultrasound (CEUS) is a sensitive and highly specific tool for detecting active bleeding. The aim of this study was to investigate the rate of detection of track microbubble flow signals on CEUS with perflubutane following liver biopsy and to assess the disappe...

متن کامل

High-intensity focused ultrasound ablation enhancement in vivo via phase-shift nanodroplets compared to microbubbles

BACKGROUND During high-intensity focused ultrasound (HIFU) surgical procedures, there is a need to rapidly ablate pathological tissue while minimizing damage to healthy tissue. Current techniques are limited by relatively long procedure times and risks of off-target heating of healthy tissue. One possible solution is the use of microbubbles, which can improve the efficiency of thermal energy de...

متن کامل

Effects of Low-Intensity Continuous Ultrasound on Hematological Parameters of Rats

Background:Low intensity ultrasound (US) has some well-known bio-effects which are of great importance to be considered.Objectives: We conducted the present study to investigate the effects of low intensity continuous ultrasound on blood cells count in rat.Methods: Rats were anesthetized and blood samples were collected before US exposure. Then, they were exposed to US with nominal intensity of...

متن کامل

Low intensity ultrasound mechanical index as a parameter affecting of ability of proliferation and collagene type 1 expression of cells

Introduction: Mechanical index (MI) is used for quantifying acoustic cavitation and the relationship between acoustic pressure and the frequency. In this study, modeling of the MI was applied to provide treatment protocol and to understand the effective physical processes on reproducibility and gene expression of fibroblast cells. Skin damage can occur of burn, cuts, abrasions ...

متن کامل

Modeling and investigating the effect of ultrasound waves pressure on the microbubble oscillation dynamics in microvessels containing an incompressible fluid (Research Article)

Understanding the dynamics of microbubble oscillation in an elastic microvessel is important for the safe and effective applications of ultrasound contrast agents in imaging and therapy. Numerical simulations based on 2D finite element model are performed to investigate the effect of acoustic parameters such as pressure and frequency on the dynamic interaction of the fluid-blood-vessel system. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014