A Novel Analytical Method for Trace Ammonium in Freshwater and Seawater Using 4-Methoxyphthalaldehyde as Fluorescent Reagent

نویسندگان

  • Ying Liang
  • Yingming Pan
  • Qing Guo
  • Hongzhi Hu
  • Chancui Wu
  • Qian Zhang
چکیده

A novel fluorescent reagent for determination of ammonium, 4-methoxyphthalaldehyde (MOPA), was successfully synthesized in this study. Under alkaline conditions, MOPA could reacted with ammonium rapidly at room temperature, producing fluorescent substance which had maximum excitation at 370 nm and emission wavelength at 454 nm. Based on this, a novel fluorescence analysis method was established for the determination of trace ammonium in natural water. Experimental parameters including reagent concentration, pH, reaction equilibrium time, and metal ions masking agent were optimized. The results showed that the optimized MOPA concentration was 0.12 g/L, pH was in the range of 11.2-12.0, and sulfite concentration was 0.051 g/L, respectively. Metal ions masking agent had no obvious effect on the fluorescence signal. With the reaction time of 15 minutes, linear range of this method was between 0.025 and 0.300 μmol/L, and the method detecting limit was 0.0058 μmol/L. The matrix recovery of the proposed method was in the range of 93.6-108.1%. Compared with the OPA method, this method was much more sensitive and rapid without the interference of background peak and would be more suitable for developing a portable fluorescence detection system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multi-element analysis of saline matrices by inductively coupled plasma mass spectrometry following on-line preconcentration using a knotted reactor.

A versatile preconcentration system for trace element determination by ICPMS was developed. It is composed of a commercial flow injection analysis system (FIAS) retrofitted with a home-made control unit containing three solenoid valves and working concomitantly with the FIAS, permitting selection and segmentation of sample, reagent, washing solution and elution flow. The knotted reactor used ha...

متن کامل

Ion-pair solid-phase extraction of trace amounts of ionic liquid cations in fresh and seawater samples.

The usefulness of ion-pair reagents in selective solid reversed-phase extraction of one N-butyl-4-methylpyridinium and four short-chain alkylimidazolium ionic liquid cations from aqueous media was investigated using various concentrations of alkylsulfonates with different alkyl chain lengths. Final recoveries of the two cations with the shortest alkyl residues were poorer than those of the othe...

متن کامل

On-line preconcentration system using mini-column packed with a chelating resin for the characterization of seasonal variations of trace elements in seawater by ICP-MS and ICP-AES.

An on-line column preconcentration technique coupled with inductively coupled plasma-mass spectrometry (ICP-MS) and -atomic emission spectrometry (ICP-AES) was developed using a mini-column (ca. 3 mm i.d., 40 mm length), that was packed with chelating resin (0.2 g) of iminodiacetic acid groups, Muromac A-1. After the preconcentration step, the column was washed with ammonium acetate buffer (pH ...

متن کامل

Determination of dissolved zinc in seawater using micro-Sequential Injection lab-on-valve with fluorescence detection.

This paper introduces the preliminary design and optimization of a micro-Sequential Injection lab-on-valve system (μSI-LOV) with fluorescence detection for the direct determination of trace Zn(2+) in an unacidified seawater matrix. The method capitalizes on the sensitivity and selectivity of FluoZin-3, which was originally designed to measure zinc in living cells. The optimum reaction condition...

متن کامل

Improved immobilization of 8-hydroxyquinoline on polyacrylonitrile fiber and application of the material to the determination of trace metals in seawater by inductively coupled plasma mass spectrometry.

A modified synthetic method has been developed for immobilization of 8-hydroxyquinoline on polyacrylonitrile fiber. The synthetic conditions, e.g. reagent concentration, reaction temperature and time, were optimized. The features of the newly-modified fiber are higher exchange capacity compared with most other materials containing immobilized 8-hydroxyquinoline, better mechanic characteristics,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015