Software-based automated measurement of susceptibility artifacts on magnetic resonance images

نویسندگان

  • Andreas Heinrich
  • Felix Guettler
چکیده

Introduction: MR-compatible implants and instruments for interventions under MR-imaging can cause susceptibility artifacts [1, 2]. Before clinical diagnostics or intervention, it must be known in what extent those artifacts could overlay the tissue of interest. For that reason, ASTM developed the standard F2119 [2] which describes how to determine the artifact’ size of passive implants. The standard defines precisely a susceptibility artifact, but gives only a vague method for artifact measurement. This had led to different methods to determine the greatest artifact, such as the categorization [3] and the assessment with measurement tools [4]. The objective was to develop a platformindependent software system for rapid, objective and reproducible measurement of susceptibility artifacts that complying with ASTM.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artifacts of Titanium, Zirconium, and Binary Titanium-Zirconium Abutments in Compute Tomography, Cone Beam Computed Tomography, and Magnetic Resonance Imaging

Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scan...

متن کامل

Comparison of Two Quantitative Susceptibility Mapping Measurement Methods Used For Anatomical Localization of the Iron-Incorporated Deep Brain Nuclei

Introduction Quantitative susceptibility mapping (QSM) is a new contrast mechanism in magnetic resonance imaging (MRI). The images produced by the QSM enable researchers and clinicians to easily localize specific structures of the brain, such as deep brain nuclei. These nuclei are targets in many clinical applications and therefore their easy localization is a must. In this study, we aimed to i...

متن کامل

An Automated MR Image Segmentation System Using Multi-layer Perceptron Neural Network

Background: Brain tissue segmentation for delineation of 3D anatomical structures from magnetic resonance (MR) images can be used for neuro-degenerative disorders, characterizing morphological differences between subjects based on volumetric analysis of gray matter (GM), white matter (WM) and cerebrospinal fluid (CSF), but only if the obtained segmentation results are correct. Due to image arti...

متن کامل

Accelerating Magnetic Resonance Imaging through Compressed Sensing Theory in the Direction space-k

Magnetic Resonance Imaging (MRI) is a noninvasive imaging method widely used in medical diagnosis. Data in MRI are obtained line-by-line within the K-space, where there are usually a great number of such lines. For this reason, magnetic resonance imaging is slow. MRI can be accelerated through several methods such as parallel imaging and compressed sensing, where a fraction of the K-space lines...

متن کامل

Fabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System

Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011