Towards a Clinical Decision Support System for External Beam Radiation Oncology Prostate Cancer Patients: Proton vs. Photon Radiotherapy? A Radiobiological Study of Robustness and Stability

نویسندگان

  • Seán Walsh
  • Erik Roelofs
  • Peter Kuess
  • Yvonka van Wijk
  • Ben Vanneste
  • Andre Dekker
  • Philippe Lambin
  • Bleddyn Jones
  • Dietmar Georg
  • Frank Verhaegen
چکیده

We present a methodology which can be utilized to select proton or photon radiotherapy in prostate cancer patients. Four state-of-the-art competing treatment modalities were compared (by way of an in silico trial) for a cohort of 25 prostate cancer patients, with and without correction strategies for prostate displacements. Metrics measured from clinical image guidance systems were used. Three correction strategies were investigated; no-correction, extended-no-action-limit, and online-correction. Clinical efficacy was estimated via radiobiological models incorporating robustness (how probable a given treatment plan was delivered) and stability (the consistency between the probable best and worst delivered treatments at the 95% confidence limit). The results obtained at the cohort level enabled the determination of a threshold for likely clinical benefit at the individual level. Depending on the imaging system and correction strategy; 24%, 32% and 44% of patients were identified as suitable candidates for proton therapy. For the constraints of this study: Intensity-modulated proton therapy with online-correction was on average the most effective modality. Irrespective of the imaging system, each treatment modality is similar in terms of robustness, with and without the correction strategies. Conversely, there is substantial variation in stability between the treatment modalities, which is greatly reduced by correction strategies. This study provides a 'proof-of-concept' methodology to enable the prospective identification of individual patients that will most likely (above a certain threshold) benefit from proton therapy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Thyroid Gland Irradiation in Women with Breast Cancer during Radiotherapy with different Radiation Energies at Supraclavicular Region

Introduction: During treatment of breast cancer, Radiotherapy to the Supraclavicular fossa region results in absorption of radiation by the thyroid gland and consequently leads to hypothyroidism in 40% of patients. The aim of this study was to compare thyroid gland radiation absorption during radiotherapy with different anterior-posterior beam radiation of 6-15 and 15-15 MV pho...

متن کامل

In vivo dosimetry of intraoral stent using TLD during external photon beam radiotherapy of oral cavity

Introduction: Individual oral stent is a mouth-opening device that used in head and neck cancer radiotherapy with the intention of decreasing radiation dose to health tissues. The aim of this study was to check the dose delivered to both the hard palate and tongue when patient uses the stent during radiotherapy of tongue carcinoma. Methods and materials<stron...

متن کامل

A Preliminary Study on the Estimation of the Number of Cancer Patients Eligible for Hadron Therapy in Iran and Fars Province

Hadron therapy (HT) with protons and carbon ions is an advanced radiotherapy technique. As the first report addressing this topic, the present study aimed to estimate the number of patients eligible for HT in Fars province and the whole of Iran. The data were collected through direct inspection of medical records of the patients treated at the Radiotherapy Department, Namazi Hospital, Shiraz, I...

متن کامل

Dosimetric Comparison of 3D Tangential Radiotherapy of Post-Lumpectomy Breast at Two Different Energies

Introduction: Radiation therapy following breast conserving surgery is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is almost always the technique of choice for this purpose. This technique is often performed based on 3D treatment planning. The aim of this study was to compare 3D treatment planning for two different energie...

متن کامل

Comparison of dosimetric and radiobiological effects of various IMRT techniques regarding to joint volume between target tissue and organs at risk in prostate cancer patients

Background: Intensity-modulated radiotherapy (IMRT) is one of the most usable methods in prostate radiotherapy that is used with different techniques. The aim of this study was to evaluate and compare the dosimetric and radiobiological effects of prostate IMRT techniques regarding to joint volume between the target tissue and organs at risk as a patients anatomical parameter. Methods: This res...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2018