Does needle calibre affect pain and complication rates in patients undergoing transperineal prostate biopsy? A prospective, randomized trial.

نویسندگان

  • Giovanni Saredi
  • Maria Chiara Sighinolfi
  • Francesco Fidanza
  • Stefano De Stefani
  • Salvatore Micali
  • Paterlini Maurizio
  • Roberto D'Amico
  • Giampaolo Bianchi
چکیده

Transperineal prostate biopsy is a procedure that can be used to obtain histological samples from the prostate. To improve both the quality of the biopsy core samples and prostate cancer detection, we are currently performing a prospective, randomized trial comparing prostate biopsy samples obtained using an 18 G-needle to those obtained using a 16 G needle. The aim of this preliminary study was to evaluate pain and complication rates in both groups in order to assess whether performing a prostate biopsy with a larger calibre needle is a feasible procedure. One hundred and eighty-seven patients undergoing transperineal prostate biopsy were prospectively evaluated and divided into two groups. The first group (94 patients, Group A) received a transperineal prostate biopsy using a 16 G-needle and the second group (93 patients, Group B) underwent transperineal prostate biopsy with an 18 G-needle. Anaesthesia was obtained with a single perineal injection at the prostatic apex in all subjects. A visual analogue scale (VAS) and facial expression scale (FES) were used to assess pain during multiple steps of the procedure in each group. A detailed questionnaire was used to obtain information about drug use because it could potentially influence the pain and complications that patients experienced. Two weeks after the procedure, early and late complications were evaluated. Statistical analysis was carried out using non-parametric tests. Prostate Specific Antigen (PSA) and drug use were similar at baseline between the two groups. Pain during prostate biopsy, which was measured with both the VAS and FES instruments, did not differ significantly between the 18- and 16 G-needle groups, and no significant differences were found in early or late complication rates between the groups. Transperineal prostate biopsy with a 16 G-needle is a feasible procedure in terms of pain and complication rates. Further studies with larger patient populations are required to assess whether or not this procedure can improve prostate cancer detection rates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison between Ultrasound Guided Transperineal and Transrectal Prostate Biopsy: A Prospective, Randomized, and Controlled Trial

This prospective study of comparing transperineal prostate biopsy (TPBx) with transrectal prostate biopsy (TRBx) was aimed to provide evidence for clinicians to select the appropriate biopsy approach under different conditions. TPBx (n = 173) and TRBx (n = 166) were performed randomly for 339 patients who were suspicious of prostate cancer (PCa). The cancer detection rate (CDR), complication ra...

متن کامل

Comparison between transrectal and transperineal prostate biopsy for detection of prostate cancer: a meta-analysis and trial sequential analysis

To systematically assess the efficacy and complications of transrectal (TR) versus transperineal (TP) prostate biopsy in the detection of prostate cancer (PCa). A meta-analysis was performed by searching the databases Pubmed, Embase and Web of science for the relevant available studies until September 1st, 2016, and thirteen studies met the inclusion criteria. The pooled odds ratios with 95% co...

متن کامل

Transperineal versus transrectal prostate biopsy: our findings in a tertiary health institution.

CONTEXT AND OBJECTIVE Prostate cancer is a major public health issue. Its incidence is rising, especially in Nigeria. Prompt diagnosis is necessary by histology. Transperineal and transrectal approaches to prostate biopsy are well-documented. Both methods are fraught with complications though, most times minor. Studies carried out to compare both methods were carried out mainly on Caucasians, g...

متن کامل

Does a new ultrasound probe change the complication rates of transrectal ultrasound-guided needle biopsies of the prostate?

BACKGROUND Transrectal ultrasound-guided prostate needle biopsies are performed to diagnose prostate cancer. This study prospectively evaluated the safety, morbidity and complication rates with two different ultrasound probes. PATIENTS AND METHODS Three huntred and thirty-two patients were biopsied using a biplane 7.5 MHz probe (GE Medical Systems Kretz Ultrasound, Zipf, Austria) and 101 pati...

متن کامل

Analgesia for Prostate Biopsy: Efficacy of Diclofenac Patch versus Diclofenac Suppository as Compared to Placebo during Prostate Biopsy

Background and Aims: Trans-rectal ultrasound guided prostate biopsy (TRUS) remains the gold standard to diagnose patients with prostate cancer. The purpose of this study is to prospectively evaluate the efficacy of diclofenac suppository versus diclofenac patch as compared to placebo, on pain reduction during prostate biopsy. Methods: A prospective, randomized, single-blind, placebo controlled ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Asian journal of andrology

دوره 11 6  شماره 

صفحات  -

تاریخ انتشار 2009