Diagnostic accuracy of UriSed automated urine microscopic sediment analyzer and dipstick parameters in predicting urine culture test results

نویسندگان

  • Kağan Huysal
  • Yasemin U. Budak
  • Ayse Ulusoy Karaca
  • Murat Aydos
  • Serdar Kahvecioğlu
  • Mehtap Bulut
  • Murat Polat
چکیده

INTRODUCTION Urinary tract infection (UTI) is one of the most common types of infection. Currently, diagnosis is primarily based on microbiologic culture, which is time- and labor-consuming. The aim of this study was to assess the diagnostic accuracy of urinalysis results from UriSed (77 Electronica, Budapest, Hungary), an automated microscopic image-based sediment analyzer, in predicting positive urine cultures. MATERIALS AND METHODS We examined a total of 384 urine specimens from hospitalized patients and outpatients attending our hospital on the same day for urinalysis, dipstick tests and semi-quantitative urine culture. The urinalysis results were compared with those of conventional semiquantitative urine culture. RESULTS Of 384 urinary specimens, 68 were positive for bacteriuria by culture, and were thus considered true positives. Comparison of these results with those obtained from the UriSed analyzer indicated that the analyzer had a specificity of 91.1%, a sensitivity of 47.0%, a positive predictive value (PPV) of 53.3% (95% confidence interval (CI) = 40.8-65.3), and a negative predictive value (NPV) of 88.8% (95% CI = 85.0-91.8%). The accuracy was 83.3% when the urine leukocyte parameter was used, 76.8% when bacteriuria analysis of urinary sediment was used, and 85.1% when the bacteriuria and leukocyturia parameters were combined. The presence of nitrite was the best indicator of culture positivity (99.3% specificity) but had a negative likelihood ratio of 0.7, indicating that it was not a reliable clinical test. CONCLUSIONS Although the specificity of the UriSed analyzer was within acceptable limits, the sensitivity value was low. Thus, UriSed urinalysis resuIts do not accurately predict the outcome of culture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High False Positives and False Negatives in Yeast Parameter in an Automated Urine Sediment Analyzer

BACKGROUND Automated urine sediment analyzers have proven their feasibility in medical laboratories. However, editing manual microscopic review of some specimens severely limits the usefulness of such systems. This study aims to give feedback on the practical experience on »Yeast«, which is one of the parameters that compel frequent manual reviews. METHODS 5448 freshly collected urine specime...

متن کامل

Automated urinalysis: first experiences and a comparison between the Iris iQ200 urine microscopy system, the Sysmex UF-100 flow cytometer and manual microscopic particle counting.

BACKGROUND Automated analysis of insoluble urine components can reduce the workload of conventional microscopic examination of urine sediment and is possibly helpful for standardization. We compared the diagnostic performance of two automated urine sediment analyzers and combined dipstick/automated urine analysis with that of the traditional dipstick/microscopy algorithm. METHODS A total of 3...

متن کامل

Improving productivity: total urinalysis vs. reflex to microscopy

have shown that omitting microscopy exams results in missed diagnosis, which of course causes repeated specimen collection and additional laboratory testing. A study authored by Nancy Brunzel and Diane Berry analyzing 709 routine specimens revealed reflexing to microscopy resulted in one in four patient samples being overlooked for pathological conditions. The authors reported the negative pred...

متن کامل

Evaluating the diagnostic value of nitrite test in comparison with U/S results in patients with urinary tract infection symptoms: A cross-sectional study

Objective: The purpose of this study is to evaluate the diagnostic value of nitrite test in comparison with urine culture (U/C) results in patients with Urinary tract infection (UTI) symptoms.Methods: This cross-sectional study was performed on 203 patients with UTI symptoms. Middle urine sample was taken into sterile plastic containers, and simultaneously the urine sample and the nitrite...

متن کامل

Performance Characteristics of Dipstick and Microscopic Urinalysis for Diagnosis of Urinary Tract Infection

Aim: Although the urine culture is used as the reference standard to determine presence or absence of urinary tract infection, the culture is an expensive and time-consuming method. The objectives of the study were to compare dipstick urinalysis with microscopic urinalysis and to compare dipstick and microscopic urinalysis results with urine culture results, by calculating performance character...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 23  شماره 

صفحات  -

تاریخ انتشار 2013