Mechanical failure because of wear or fracture of the polyethylene tibial post in posteriorly-stabilised total knee replacements has been extensively described. In this study of 12 patients with a clinically and radiologically successful NexGen LPS posteriorly-stabilised prosthesis impingement of the anterior tibial post was evaluated in vivo in three dimensions during gait using radiologically-based image-matching techniques. Impingement was observed in all images of the patients during the stance phase, although the NexGen LPS was designed to accommodate 14 degrees of hyperextension of the component before impingement occurred. Impingement arises as a result of posterior translation of the femur during the stance phase. Further attention must therefore be given to the configuration of the anterior portion of the femoral component and the polyethylene post when designing posteriorly-stabilised total knee replacements.
منابع مشابه
Post impingement in posterior stabilised total knee arthroplasty.
Posterior stabilised implants are a well-proven treatment for patients requiring primary total knee arthroplasty. Concerns about the posterior stabilised (PS) design have been raised and recent studies suggest that the post-cam articulation can be an additional source of polyethylene wear debris. In this study, the authors report impingement of the tibial post against the patellar component in ...
متن کاملPosteriorly stabilised total-condylar knee replacement. Three to eight years' follow-up of 85 knees.
We have reviewed 85 knees in 71 patients after total-condylar posteriorly stabilised (Insall-Burstein) knee replacement with an average follow-up of five years. Excellent or good results were obtained in 90% with an average maximum flexion of 98 degrees. The four poor results (5%) included two with deep infection, one with patellar dislocation and one with loosening. Four other knees (5%) showe...
متن کاملIn vivo kinematics of total knee arthroplasty. Concave versus posterior-stabilised tibial joint surface.
We studied the kinetics of the knee in 20 patients (22 knees) 12 months after total knee arthroplasty (TKA), by using three-dimensional radiostereometry and film-exchanger techniques. Eleven knees had a concave (constrained) tibial implant and 11 a posterior-stabilised prosthesis. Eleven normal knees served as a control group. In the posterior-stabilised knees there was less proximal and poster...
متن کاملEvaluation of Anterior Tibial Post Impingement during Gait in Posterior-stabilzed Total Knee Arthroplasty
Introduction: Posterior-stabilized total knee arthroplasty (TKA) has been widely used since its introduction nearly three decades ago, and long-term follow-up studies have reported satisfactory results. However, mechanical failure due to fracture of the tibial post recently has been described in several reports (1). The possible fracture mechanism was the repeated impingement between the interc...
متن کاملAnterior dislocation of Insall Burstein II total knee arthroplasty secondary to polyethylene tibial post fracture: a case report.
Anterior dislocation of a posterior stabilised total knee arthroplasty secondary to a polyethylene tibial post fracture is rare. We report one such case in an 89-year-old Chinese woman who had undergone total knee arthroplasty using the Insall Burstein II prosthesis 7 years earlier. The failure was due to sagittal malalignment of the components. Owing to more pronounced anterior bowing of the d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 90 9 شماره
صفحات -
تاریخ انتشار 2008