Knitted nitinol represents a new generation of constrictive external vein graft meshes.

نویسندگان

  • Peter Zilla
  • Loven Moodley
  • Michael F Wolf
  • Deon Bezuidenhout
  • Mazin S Sirry
  • Nasser Rafiee
  • Wilhelm Lichtenberg
  • Melanie Black
  • Thomas Franz
چکیده

OBJECTIVE Constriction of vein grafts with braided external nitinol meshes had previously led to the successful elimination of neointimal tissue formation. We investigated whether pulse compliance, smaller kink-free bending radius, and milder medial atrophy can be achieved by knitting the meshes rather than braiding, without losing the suppressive effect on intimal hyperplasia. METHODS Pulse compliance, bending stiffness, and bending radius, as well as longitudinal-radial deformation-coupling and radial compression, were compared in braided and knitted nitinol meshes. Identical to previous studies with braided mesh grafts, a senescent nonhuman primate model (Chacma baboons; bilateral femoral interposition grafts/6 months) mimicking the clinical size mismatch between vein grafts and runoff arteries was used to examine the effect of knitted external meshes on vein grafts: nitinol mesh-constricted (group 1); nitinol mesh-constricted and fibrin sealant (FS) spray-coated for mesh attachment (group 2); untreated control veins (group 3), and FS spray-coated control veins (group 4). RESULTS Compared with braided meshes, knitted meshes had 3.8-times higher pulse compliance (3.43 ± 0.53 vs 0.94 ± 0.12%/100 mm Hg; P = .00002); 30-times lower bending stiffness (0.015 ± 0.002 vs 0.462 ± 0.077 Nmm(2); P = .0006); 9.2-times narrower kink-free bending radius (15.3 ± 0.4 vs 140.8 ± 22.4 mm; P = .0006), and 4.3-times lower radial narrowing caused by axial distension (18.0% ± 1.0% vs 77.0% ± 3.7%; P = .00001). Compared with mesh-supported grafts, neointimal tissue was 8.5-times thicker in group I (195 ± 45 μm) vs group III (23.0 ± 21.0 μm; P < .001) corresponding with a 14.3-times larger neointimal area in group I (4330 ± 957 × 103 μm(2)) vs group III (303 ± 221× 103 μm(2); P < .00004). FS had no significant influence. Medial muscle mass remained at 43.4% in knitted meshes vs the 28.1% previously observed in braided meshes. CONCLUSION Combining the suppression of intimal hyperplasia with a more physiologic remodeling process of the media, manifold higher kink-resistance, and lower fraying than in braided meshes makes knitted nitinol an attractive concept in external vein graft protection.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A computational study of knitted Nitinol meshes for their prospective use as external vein reinforcement.

External reinforcement has been suggested for autologous vein grafts to address the mismatch of mechanical properties and fluid dynamics of graft and host vessel, a main factor for graft failure. A finite-element tool was developed to investigate the mechanical behaviour, in particular radial compliance, of knitted Nitinol meshes (internal diameter: 3.34 mm) with two different knit designs (eve...

متن کامل

Tailored sizes of constrictive external vein meshes for coronary artery bypass surgery.

External mesh constriction of vein grafts was shown to mitigate intimal hyperplasia by lowering circumferential wall stress and increasing fluid shear stress. As under-constriction leaves vein segments unsupported and thus prone to neointimal proliferation while over-constriction may cause wall folding optimal mesh sizing holds a key to clinical success. Diameter fluctuations and the occurrence...

متن کامل

Computerized tomographic angiography in patients having eSVS Mesh® supported coronary saphenous vein grafts: intermediate term results

BACKGROUND The Saphenous Vein (SVG) is used in over 80% of coronary artery bypass procedures (CABG) and SVG patency is the Achilles heel of CABG. To address this issue, the eSVS Mesh(R), an external Nitinol knitted mesh, fitted like a sleeve over the vein graft preventing over expansion in the high pressure arterial system, has been introduced to improve disease management. Patency data is limi...

متن کامل

Endovascular Treatment for Infra-inguinal Autologous Saphenous Vein Graft Occlusion Using Self Expanding Nitinol Stents

INTRODUCTION For patients with infra-inguinal autologous vein bypass graft occlusion, conventional open surgical repair or endovascular treatment (EVT) for native vessel occlusion have generally been performed. REPORT A 73 year old female with non-healing ulcer and gangrene of the left lower leg was diagnosed as having infra-inguinal autologous saphenous vein graft occlusion. In this case, su...

متن کامل

Enhanced endothelialization of Dacron grafts by external vein wrapping.

The efficacy of external vein wrapping of vascular grafts in promoting the development of a luminal endothelial surface was assessed in 12 dogs who underwent thoracoabdominal bypasses with 26-29 cm X 6-mm i.d. double-velour knitted Dacron grafts. In group I (n = 6) 6-cm segments of the grafts were wrapped with autologous jugular vein with its endothelial surface applied against the outside of t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of vascular surgery

دوره 54 5  شماره 

صفحات  -

تاریخ انتشار 2011